06.08.2015 Views

IBM XIV Storage System Copy Services and Migration

IBM XIV Storage System: Copy Services and Migration - Common ...

IBM XIV Storage System: Copy Services and Migration - Common ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Zone or cable the <strong>XIV</strong> to the non-<strong>XIV</strong> storage deviceBecause the non-<strong>XIV</strong> storage device views the <strong>XIV</strong> as a host, the <strong>XIV</strong> must connect to thenon-<strong>XIV</strong> storage system as a SCSI initiator. Therefore, the physical connection from the <strong>XIV</strong>must be from initiator ports on the <strong>XIV</strong> (which by default for Fibre Channel is port 4 on eachactive interface module). The initiator ports on the <strong>XIV</strong> can be directly attached to the non-<strong>XIV</strong>storage (without an intervening switch) or they may be fabric attached (it which case they willneed to be zoned to the non-<strong>XIV</strong> storage system). Two physical connections from twoseparate modules on two separate fabrics are recommended for redundancy (althoughredundant pathing will not be possible on active/passive controllers).It is also possible that the host may be attached via one medium (such as iSCSI), whereasthe migration occurs via the other (such as Fibre Channel). The host-to-<strong>XIV</strong> connectionmethod <strong>and</strong> the data migration connection method are independent of each other.Depending on the non-<strong>XIV</strong> storage device vendor <strong>and</strong> device, it may be easier to zone the<strong>XIV</strong> to the ports where the volumes being migrated are already present. In this manner noreconfiguration of the non-<strong>XIV</strong> storage device may be required. For example, in EMCSymmetrix/DMX environments, it is easier to zone the fiber adapters (FAs) to the <strong>XIV</strong> wherethe volumes are already mapped.At the completion of this step you will have:1. Run cables from port 4 on each selected <strong>XIV</strong> interface module to either a fabric switch ordirectly to the non-<strong>XIV</strong> storage (if the non-<strong>XIV</strong> storage has free host ports <strong>and</strong> it supportsdirect attach).2. Zoned the <strong>XIV</strong> initiator ports (whose WWPNs end in 3) to the selected non-<strong>XIV</strong> storagedevice host ports using single initiator zoning (each zone contains one initiator port <strong>and</strong>one target port).Chapter 7. Data migration 191

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!