06.08.2015 Views

IBM XIV Storage System Copy Services and Migration

IBM XIV Storage System: Copy Services and Migration - Common ...

IBM XIV Storage System: Copy Services and Migration - Common ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

In Example 7-10 the XCLI comm<strong>and</strong>s show that the target called ITSO_DS4700 has two ports,one from controller A (201800A0B82647EA) <strong>and</strong> one from controller B (201900A0B82647EA).This is not the correct configuration <strong>and</strong> should not be used.Example 7-10 Incorrect definition, as target has ports to both controllers>> target_listName SCSI Type ConnectedITSO_DS4700 FC yes>> target_port_list target=ITSO_DS4700_Ctrl_BTarget Name Port Type Active WWPN iSCSI Address iSCSI PortITSO_DS4700 FC yes 201800A0B82647EA 0ITSO_DS4700 FC yes 201900A0B82647EA 0Instead, two targets should have been defined, as shown in Example 7-11. In this example,two separate targets have been defined, each target having only one port for the relevantcontroller.Example 7-11 Correct definitions for a DS4700> target_listName SCSI Type ConnectedITSO_DS4700_ctrl_A FC yesITSO_DS4700_ctrl_B FC yes>> target_port_list target=ITSO_DS4700_Ctrl_ATarget Name Port Type Active WWPN iSCSI Address iSCSI PortITSO_DS4700 FC yes 201800A0B82647EA 0>> target_port_list target=ITSO_DS4700_Ctrl_ATarget Name Port Type Active WWPN iSCSI Address iSCSI PortITSO_DS4700 FC yes 201900A0B82647EA 0Defining the <strong>XIV</strong> to the DS4000 as a hostUse the DS <strong>Storage</strong> Manager to check the profile of the DS4000 <strong>and</strong> select a host type forwhich ADT is disabled or failover mode is RDAC. To display the profile from the DS <strong>Storage</strong>Manager choose <strong>Storage</strong> Subsystem View Profile All. Then go to the bottom of theProfile panel. The profile may vary according to NVRAM version. In Example 7-12 select thehost type for which ADT status is disabled (Windows 2000).Example 7-12 Earlier NVRAM versionsHOST TYPELinuxWindows 2000/Server 2003/Server 2008 Non-ClusteredADT STATUSEnabledDisabledIn Example 7-13 choose the host type that specifies RDAC (Windows 2000).Example 7-13 Later NVRAM versionsHOST TYPELinuxWindows 2000/Server 2003/Server 2008 Non-ClusteredFAILOVER MODEADTRDAC228 <strong>IBM</strong> <strong>XIV</strong> <strong>Storage</strong> <strong>System</strong>: <strong>Copy</strong> <strong>Services</strong> <strong>and</strong> <strong>Migration</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!