06.08.2015 Views

IBM XIV Storage System Copy Services and Migration

IBM XIV Storage System: Copy Services and Migration - Common ...

IBM XIV Storage System: Copy Services and Migration - Common ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Using Microsoft calculator to convert hex to decimalStart the calculator with the following steps:1. Selecting Program Files Programs Accessories Calculator.2. From the View drop-down menu change from St<strong>and</strong>ard to Scientific.3. Select Hex.4. Enter a hexadecimal number <strong>and</strong> then select Dec.The hexadecimal number will have been converted to decimal.Given that the <strong>XIV</strong> supports migration from almost any storage device, it is impossible to listthe methodology to get LUN IDs from each one.7.12.1 EMC CLARiiONThe following considerations were identified specifically for EMC CLARiiON:► LUN0There is no requirement to map a LUN to LUN ID 0 for the CLARiiON to communicate withthe <strong>XIV</strong>.► LUN numberingThe EMC CLARiiON uses decimal LUN numbers for both the CLARiiON ID <strong>and</strong> the hostID (LUN number).► MultipathingThe EMC CLARiiON is an active/passive storage device. This means that each storageprocessor (SP-A <strong>and</strong> SP-B) must be defined as a separate target to the <strong>XIV</strong>. You couldchoose to move LUN ownership of all the LUNs that you are migrating to a specific SP <strong>and</strong>simply define only that SP as a target. Moving a LUN away from the SP that owns it isknown as trespassing. Have only one path to each SP.► Requirements when defining the <strong>XIV</strong>If migrating from an EMC CLARiiON use the settings shown in Table 7-4 to define the <strong>XIV</strong>to the CLARiiON. Ensure that Auto-trespass is disabled for every <strong>XIV</strong> initiator port(WWPN) registered to the Clariion.Table 7-4 Defining an <strong>XIV</strong> to the EMC CLARiiONInitiator informationRecommended settingInitiator typeHBA typeArray CommPathCLARiiON OpenHostEnabledFailover mode 0Unit serial numberArray7.12.2 EMC Symmetrix <strong>and</strong> DMXThe considerations discussed in this section were identified specifically for EMC Symmetrix<strong>and</strong> DMX.224 <strong>IBM</strong> <strong>XIV</strong> <strong>Storage</strong> <strong>System</strong>: <strong>Copy</strong> <strong>Services</strong> <strong>and</strong> <strong>Migration</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!