Phonecell <strong>SX4e</strong> Programming - continued<br />
Enter On-Hook Call Alert Cadence Option<br />
Use the following key sequence to program the on-hook call alert ring<br />
cadence:<br />
Press: # * 30 * * #<br />
Both the on-time and off-time durations are programmed in 100 ms<br />
increments from 1 to 255 (0.1 - 25.5 seconds). If the value is not<br />
between 1 and 255, inclusive, it will be considered invalid. The factory<br />
default is 20 and 40, respectively.<br />
Enter On-Hook Call Alert Frequency Option<br />
Use the following key sequence to program the on-hook call alert ring<br />
frequency:<br />
Press: # * 32 * #<br />
The frequency value is set to 0 for 20 Hz, 1 for 25 Hz, and 2 for 50 Hz.<br />
If the frequency value is greater than 2, it will be considered invalid.<br />
The factory default is 0.<br />
Enter Audio Input Impedance Option<br />
Use the following key sequence to select the audio input impedance:<br />
Press: # * 68 * #<br />
The audio Z value is set to 0 for 600 ohms, 1 for 900 ohms. If the<br />
value is neither 0 nor 1, it is considered invalid. The factory default is 0.<br />
Enter Ring Back Request<br />
Use the following key sequence to request immediate ring back:<br />
Press: # * 13 * #<br />
There is no ring back value to be set; the <strong>com</strong>mand activates when the<br />
phone is placed back on-hook.<br />
Enter Restore Factory Defaults Request<br />
Use the following key sequence to request restoration of all factory set<br />
default values (including the SIM PIN auto entry value):<br />
Press: # * 15 * #<br />
There is no restore defaults value to be entered; the <strong>com</strong>mand<br />
activates immediately. If a value is entered, it is considered invalid and<br />
the Phonecell will not restore the factory defaults.<br />
Enter Periodic Self Test Option<br />
Use the following key sequence to program periodic self test:<br />
Press: # * 76 * #<br />
The self-test interval is programmed in 1 minute increments from 1 to<br />
65,535. A value of 0 disables periodic self test. If the value is not<br />
between 0 and 65,535, inclusive, it will be considered invalid. The<br />
factory default is 180.<br />
<strong>SX4e</strong> <strong>GSM</strong> 1900 41 USER MANUAL