(B) Heating<br />

b. Heating<br />

Poor heating<br />

Cold air is<br />

discharged.<br />

Cold draft prevention<br />

is not working.<br />

Refrigerant flow<br />

failure<br />

Not enough<br />

air circulation<br />

Is setting temp.<br />

suitable ?<br />

Is heating load<br />

too large ?<br />

4-way valve is<br />

defective.<br />

Refrigerant<br />

shortage<br />

Electronic refrigerant<br />

control valve is defective.<br />

Compressor is defective.<br />

Service valves are not<br />

fully open.<br />

Air filter<br />

is clogged.<br />

Is fan speed<br />

set to LOW ?<br />

Refrigerant tubes between<br />

indoor and outdoor units<br />

are not insulated.<br />

4-way valve is<br />

defective.<br />

“ STANDBY ” is<br />

displayed.<br />

Indoor coil sensor E2 is<br />

defective.<br />

IV - 6<br />

4. Service procedures<br />

Change the setting temp.<br />

Review heating load<br />

estimate.<br />

Replace the valve.<br />

Charge with<br />

refrigerant.<br />

Replace the valve.<br />

Replace the compressor.<br />

Open the valves fully.<br />

Clean the filter.<br />

Set the fan speed to<br />

either MEDIUM or HIGH.<br />

Insulate wide and narrow<br />

tubes separately.<br />

Replace the valve.<br />

Replace indoor<br />

P.C.B. Ass'y.<br />

Replace the sensor.<br />