1-7 Cooling Capacity<br />
Indoor Unit : ASR 425 H Outdoor Unit : AER 425 SCLE<br />
AER 425 SHLE<br />
1. Specifications<br />
RATING CAPACITY : 7.3 kW AIR FLOW RATE : 1140 CMH<br />
EVAPORATOR CONDENSER<br />
ENT. TEMP. °C AMBIENT TEMP °C<br />
WB DB 25 30 35 40 45<br />
TC 7.37 7.03 6.67 6.26 5.81<br />
CI 2.22 2.37 2.55 2.49 2.45<br />
21 SHC 4.66 4.47 4.28 4.06 3.83<br />
15 23 SHC 5.21 5.03 4.83 4.61 4.39<br />
25 SHC 5.77 5.58 5.39 5.17 4.94<br />
27 SHC 6.33 6.14 5.95 5.73 5.5<br />
29 SHC 6.88 6.7 6.51 6.26 5.81<br />
31 SHC 7.37 7.03 6.67 6.26 5.81<br />
TC 7.61 7.31 6.96 6.59 6.18<br />
CI 2.28 2.44 2.62 2.57 2.52<br />
21 SHC 3.93 3.78 3.6 3.42 3.23<br />
17 23 SHC 4.49 4.34 4.16 3.98 3.78<br />
25 SHC 5.05 4.89 4.72 4.54 4.34<br />
27 SHC 5.6 5.45 5.28 5.09 4.9<br />
29 SHC 6.16 6.01 5.83 5.65 5.46<br />
31 SHC 6.72 6.56 6.39 6.21 6.01<br />
TC 7.88 7.6 # 7.3 6.94 6.54<br />
CI 2.35 2.52 2.7 2.66 2.62<br />
21 SHC 3.21 3.08 2.94 2.77 2.6<br />
19 23 SHC 3.76 3.63 3.49 3.33 3.16<br />
25 SHC 4.32 4.19 4.05 3.89 3.71<br />
27 SHC 4.88 4.75 4.61 4.45 4.27<br />
29 SHC 5.44 5.31 5.17 5 4.83<br />
31 SHC 5.99 5.86 5.72 5.56 5.39<br />
TC 8.14 7.85 7.56 7.21 6.86<br />
CI 2.41 2.59 2.78 2.74 2.7<br />
23 SHC 3.03 2.91 2.78 2.64 2.5<br />
21 25 SHC 3.59 3.47 3.34 3.2 3.05<br />
27 SHC 4.15 4.03 3.9 3.75 3.61<br />
29 SHC 4.7 4.58 4.46 4.31 4.17<br />
31 SHC 5.26 5.14 5.01 4.87 4.73<br />
TC 8.42 8.17 7.88 7.59 7.24<br />
CI 2.48 2.65 2.85 2.82 2.78<br />
23 25 SHC 2.86 2.76 2.65 2.54 2.41<br />
27 SHC 3.42 3.32 3.21 3.1 2.97<br />
29 SHC 3.97 3.88 3.77 3.65 3.52<br />
31 SHC 4.53 4.44 4.32 4.21 4.08<br />
TC 8.76 8.45 8.2 7.91 7.61<br />
CI 2.56 2.74 2.91 2.9 2.88<br />
25 27 SHC 2.71 2.6 2.51 2.41 2.3<br />
29 SHC 3.27 3.15 3.06 2.97 2.86<br />
31 SHC 3.82 3.71 3.62 3.52 3.42<br />
TC : Total Cooling Capacity (kW)<br />
SHC : Sensible Heat Capacity (kW)<br />
CI : Compressor Input (kW)<br />
Rating conditions are<br />
: Outdoor Ambient Temp. 35 °C DB<br />
: Indoor Unit Entering Air Temp. 27 °C DB / 19 °C WB<br />