08.12.2012 Views

1 2 3 4 5

1 2 3 4 5

1 2 3 4 5

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1<br />

12<br />

3<br />

4<br />

5<br />

1-1 Unit Specifications<br />

Concealed Duct Type<br />

I - 26<br />

1. Specifications<br />

MODEL No. Indoor Unit ADR 425 H<br />

Outdoor Unit AER 425 SCLE<br />

POWER SOURCE 220 - 230 - 240 V / 1 phase / 50 Hz<br />

PERFORMANCE Cooling<br />

Capacity kW 7.3<br />

BTU / h 25,000<br />

Air circulation (Hi / Me / Lo) m3 /h 1,080 / 900 / 780<br />

Moisture removal (High) Liters/h 3.5<br />

External static pressure (High)<br />

ELECTRICAL RATINGS<br />

mmAq(Pa) 5.1 (50) : at shipment, 9.4 (92) : using the booster cable<br />

Voltage rating VAC 220 230 240<br />

Available voltage range VAC 198 – 264<br />

Running amperes* A 14.65 14.6 14.54<br />

Max. running amperes** A 15.65 15.5 15.44<br />

Power input kW 3.01 3.14 3.21<br />

Power factor % 93.4 93.5 92<br />

C.O.P W / W 2.43 2.32 2.27<br />

Max. starting amperes<br />

FEATURES<br />

A 69 72 75<br />

Controls / Thermostat control Microprocessor<br />

Timer ON / OFF 72-hours<br />

Fan speeds Indoor / Outdoor 3 and Automatic control / 3 (Auto)<br />

Airflow direction (Indoor) —<br />

Air filter Field supply<br />

Remote controller (Option) Wired : REM HW A<br />

Refrigerant control Electronic expansion valve<br />

Drain pump (Drain connection) Max. head 75 cm above unit bottom (25A, OD32 mm)<br />

Compressor Rotary (Sanyo)<br />

Operation sound Indoor - Hi/Me/Lo dB - A 34 / 30 / 27, (38 / 34 / 30 : using the booster cable)<br />

Outdoor - Hi dB - A 52<br />

Color (Approximate value) Indoor —<br />

REFRIGERANT TUBING<br />

Outdoor Munsell 5Y8.4 / 0.5, RAL 9002-GL<br />

Limit of tubing length m (ft.) 50 (164 )<br />

Limit of tubing length at shipment m (ft.) 30 ( 98 )<br />

Limit of elevation difference m (ft.) Outdoor unit is higher than indoor unit : 50 (164)<br />

between the two units Outdoor unit is lower than indoor unit : 30 (98)<br />

Refrigerant tube Narrow tube mm (in.) 6.35 (1 / 4)<br />

outer diameter Wide tube mm (in.) 15.88 (5 / 8)<br />

Refrigerant amount at shipment kg R407C - 3.2<br />

DIMENSIONS & WEIGHT Indoor unit Outdoor unit<br />

Unit dimensions Height mm (in.) 310 ( 12 - 7 / 32) 735 (28 - 30 / 32)<br />

Width mm (in.) 1,000 ( 39 - 12 / 32) 940 (37 )<br />

Depth mm (in.) 630 ( 24 - 26 / 32) 340 (13 - 12 / 32)<br />

Package dimensions Height mm (in.) 358 ( 14 - 3 / 32) 826 (32 - 17 / 32)<br />

Width mm (in.) 1,191 ( 46 - 28 / 32) 1,016 (40 )<br />

Depth mm (in.) 783 ( 30 - 26 / 32) 416 (16 - 12 / 32)<br />

Net weight kg (lb.) 32 ( 71 ) 69 ( 152 )<br />

Shipping weight kg (lb.) 37 ( 82 ) 75 ( 165 )<br />

Shipping volume m3 (cu. ft) 0.334 (11.8) 0.349 (12.3)<br />

DATA SUBJECT TO CHANGE WITHOUT NOTICE.<br />

Cooling:<br />

Rating conditions (*): Indoor air temperature 27 °C DB/19 °C WB, Outdoor air temperature 35 °C DB<br />

Full load conditions (**): Indoor air temperature 32 °C DB/23 °C WB, Outdoor air temperature 43 °C DB