1-11 Installation Instructions<br />
Electrical Characteristics<br />
Indoor Unit: ACR 425 H Outdoor Unit : AER 425 SCLE<br />
AER 425 SHLE<br />
● Cooling<br />
Indoor Unit Outdoor Unit<br />
Fan Motor Fan Motor Compressor<br />
Cooling:<br />
Rating Conditions : Indoor Air Temperature 27°C DB / 19°C WB<br />
Outdoor Air Temperature 35°C DB<br />
Full Load Conditions : Indoor Air Temperature 35°C DB / 23°C WB<br />
Heating:<br />
Outdoor Air Temperature 43°C DB<br />
Rating Conditions : Indoor Air Temperature 20°C DB<br />
Outdoor Air Temperature 7°C DB / 6°C WB<br />
Full Load Conditions : Indoor Air Temperature 24°C DB<br />
Outdoor Air Temperature 21°C DB / 15.5°C WB<br />
I - 111<br />
1. Specifications<br />
Complete Unit<br />
Performance at 220 - 240 V / 1 phase / 50 Hz 380 - 415 V / 1 phase / 50 Hz<br />
Rating conditions<br />
Full load conditions<br />
A 0.43 / 0.43 0.62 / 0.65 12.1 / 12.3 13.15 / 13.38<br />
kW 90 / 100 0.13 / 0.15 2.55 / 2.7 2.77 / 2.95<br />
A 0.43 / 0.43 0.62 / 0.65 13.44 / 13.48 14.49 / 14.56<br />
kW 90 / 100 0.13 / 0.15 2.8 / 2.88 3.02 / 3.13<br />
Starting amperes A 1 / 1 1 / 1 67 / 73 69 / 75<br />
● Heating (Heat pump only)<br />
Indoor Unit Outdoor Unit<br />
Fan Motor Fan Motor Compressor<br />
Complete Unit<br />
Performance at 220 - 240 V / 1 phase / 50 Hz 380 - 415 V / 1 phase / 50 Hz<br />
Rating conditions<br />
Full load conditions<br />
A 0.33 / 0.34 0.62 / 0.65 13.7 / 13.5 14.65 / 14.49<br />
kW 70 / 80 0.13 / 0.15 2.86 / 2.96 3.06 / 3.19<br />
A 0.33 / 0.34 0.62 / 0.65 15.6 / 15.2 16.55 / 16.19<br />
kW 70 / 80 0.13 / 0.15 3.25 / 3.29 3.45 / 3.52<br />
Starting amperes A 1 / 1 1 / 1 67 / 73 69 / 75<br />