Technical Data and Speed-Torque Diagrams<br />
3.1 Speed-torque diagrams<br />
Table 3-45 <strong>1FT6</strong>163 force ventilated<br />
<strong>1FT6</strong>163<br />
Technical data Code Units -8SB7 -8SD7<br />
Engineering data<br />
Rated speed<br />
No. of poles<br />
Rated torque (100K)<br />
Rated current (100K)<br />
Stall torque (60K)<br />
Stall torque (100K) 1)<br />
Stall current (60K)<br />
Stall current (100K)<br />
Moment of inertia (with brake)<br />
Moment of inertia (without brake)<br />
Optimum operating point<br />
Optimum speed<br />
Optimum power<br />
Limiting data<br />
Max. permissible speed (mech.)<br />
Max. torque<br />
Max. current 1)<br />
Physical constants<br />
Torque constant<br />
Voltage constant<br />
Winding resistance at 20° C<br />
Rotating field inductance<br />
Electrical time constant<br />
Shaft torsional stiffness<br />
Mechanical time constant<br />
Thermal time constant<br />
Weight with brake<br />
Weight without brake<br />
nN<br />
2p<br />
MN(100K)<br />
IN (100K)<br />
M0 (60K)<br />
M0 (100K)<br />
I0 (60K)<br />
I0 (100K)<br />
Jmot<br />
Jmot<br />
nopt<br />
Popt<br />
nmax<br />
Mmax<br />
Imax<br />
kT<br />
kE<br />
Rph<br />
LD<br />
Tel<br />
ct<br />
Tmech<br />
Tth<br />
m<br />
m<br />
RPM<br />
Nm<br />
A<br />
Nm<br />
Nm<br />
A<br />
A<br />
10 –4 kgm 2<br />
10 –4 kgm 2<br />
RPM<br />
kW<br />
RPM<br />
Nm<br />
A<br />
Nm/A<br />
V/1000 RPM<br />
Ohm<br />
mH<br />
ms<br />
Nm/rad<br />
ms<br />
min<br />
kg<br />
kg<br />
1500<br />
8<br />
385<br />
136<br />
360<br />
425<br />
124<br />
151<br />
––<br />
2300<br />
1500<br />
60.5<br />
3100<br />
900<br />
372<br />
2.81<br />
186<br />
0.026<br />
0.81<br />
31<br />
472100<br />
2.3<br />
25<br />
––<br />
170<br />
1) Observe the maximum and rated current of the drive converter<br />
2500<br />
8<br />
340<br />
185<br />
360<br />
425<br />
186<br />
226<br />
––<br />
2300<br />
2500<br />
89.0<br />
3100<br />
900<br />
558<br />
1.88<br />
124<br />
0.012<br />
0.36<br />
30<br />
472100<br />
2.3<br />
25<br />
––<br />
170<br />
<strong>1FT6</strong> synchronous motors<br />
3-90 <strong>Configuration</strong> <strong>Manual</strong>, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0