Motor Components (Options)<br />

4.1 Thermal motor protection<br />

Caution<br />

The integrated temperature sensor protects the synchronous against an overload condition<br />

Shaft heights, 28 to 48 up to 2 ∙ I060 K and speed 0<br />

from shaft height 63 up to 4∙ I0 60 K and speed 0<br />

For load applications that are critical from a thermal perspective - e.g. overload when the<br />

motor is stationary or an overload of 4 ∙ M0 longer than 4 s, adequate protection is no longer<br />

available. This is the reason that additional protection must be provided.<br />

R[k� �<br />

�<br />

�<br />

�<br />

�<br />

�������<br />

I�<br />

��� ��� ��� � ��[<br />

���<br />

Figure 4-1 Resistance characteristic of the KTY 84 as a function of the temperature<br />

<strong>1FT6</strong> synchronous motors<br />

4-2 <strong>Configuration</strong> <strong>Manual</strong>, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0