Motor Components (Options)<br />

4.4 <strong>Motors</strong> without DRIVE-CLiQ<br />

4.4.3 Resolvers<br />

Notice<br />

A max. operating frequency of 470 Hz must be maintained for SINAMICS S120.<br />

Function:<br />

• Speed actual value sensing<br />

• Rotor position encoder for inverter control<br />

• Indirect incremental measuring system for the position control loop<br />

Table 4-9 Technical data, resolvers<br />

Features Resolvers<br />

Mech. limiting speed 15 000 RPM<br />

Excitation voltage 5 V (rms) to 13 V (rms)<br />

Excitation frequency 4 kHz to 10 kHz<br />

Current consumption < 80 mA (rms)<br />

Angular accuracy (bandwidth)<br />

2-pole<br />

multi-pole<br />

Pole number<br />

(The pole number is identical<br />

with the motor pole<br />

number)<br />

< 14'<br />

< 4'<br />

Ratio 0.5<br />

� ����������������<br />

�������������<br />

Figure 4-4 Output signals, resolver<br />

2, 4, 6 or 8<br />

���������� � ����������������<br />

�������������<br />

<strong>1FT6</strong> synchronous motors<br />

4-10 <strong>Configuration</strong> <strong>Manual</strong>, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0