Motor Description<br />

1.7 Cooling<br />

Forced ventilation, SH 132<br />

Forced ventilation, SH 160<br />

Air flow direction from DE to NDE<br />

The air is blown through the enclosure corners of the extruded profile using a mounted radial<br />

fan.<br />

Connection: via terminal box<br />

Supply voltage: 3-ph. 400/480 V AC, 50/60 Hz<br />

Maximum current: 0.4 A<br />

Air flow direction from DE to NDE<br />

The air is blow through the enclosure corners of the extruded profile<br />

using a mounted radial<br />

fan.<br />

Connection: via terminal box<br />

Supply voltage: 3-ph. 400/480 V AC, 50/60 Hz<br />

Maximum current: 0.8 A<br />

Minimum clearance between parts and components mounted by the customer and the air discharge<br />

opening<br />

The following minimum clearance must be maintained between parts and components<br />

mounted by the customer and the air discharge opening:<br />

Table 1-8 Minimum clearance to parts and components mounted by the customer<br />

Shaft height [mm] Minimum clearance [mm]<br />

80 20<br />

100 30<br />

132 60<br />

160 80<br />

<strong>1FT6</strong> synchronous motors<br />

1-22 <strong>Configuration</strong> <strong>Manual</strong>, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0