Configuration Manual Synchronous Motors 1FT6 - Siemens ...
Configuration Manual Synchronous Motors 1FT6 - Siemens ...
Configuration Manual Synchronous Motors 1FT6 - Siemens ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Motor Description<br />
1.7 Cooling<br />
Forced ventilation, SH 132<br />
Forced ventilation, SH 160<br />
Air flow direction from DE to NDE<br />
The air is blown through the enclosure corners of the extruded profile using a mounted radial<br />
fan.<br />
Connection: via terminal box<br />
Supply voltage: 3-ph. 400/480 V AC, 50/60 Hz<br />
Maximum current: 0.4 A<br />
Air flow direction from DE to NDE<br />
The air is blow through the enclosure corners of the extruded profile<br />
using a mounted radial<br />
fan.<br />
Connection: via terminal box<br />
Supply voltage: 3-ph. 400/480 V AC, 50/60 Hz<br />
Maximum current: 0.8 A<br />
Minimum clearance between parts and components mounted by the customer and the air discharge<br />
opening<br />
The following minimum clearance must be maintained between parts and components<br />
mounted by the customer and the air discharge opening:<br />
Table 1-8 Minimum clearance to parts and components mounted by the customer<br />
Shaft height [mm] Minimum clearance [mm]<br />
80 20<br />
100 30<br />
132 60<br />
160 80<br />
<strong>1FT6</strong> synchronous motors<br />
1-22 <strong>Configuration</strong> <strong>Manual</strong>, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0