Motor Description<br />
1.3 Technical features, options, supplements<br />
1.3 Technical features, options, supplements<br />
Table 1-2 Options and supplements<br />
Technical feature Version<br />
Type of construction<br />
(acc. to EN60034–7; IEC 60034–7)<br />
Degree of protection 4)<br />
(acc. to EN 60034–5; IEC 60034–5)<br />
Shaft end<br />
(acc. to EN and IEC 60034–14)<br />
Radial eccentricity, concentricity and<br />
axial eccentricity<br />
(acc. to DIN 42955; IEC 60072-1)<br />
Vibration severity<br />
(acc. to EN 60034-14; IEC 60034-14)<br />
IM B14 for SH 63 to 100<br />
IP65, IP67, IP68<br />
Information: SH 28 is only available in degree of protection IP64 or IP67.<br />
IP67 and IP68 with sealing air connection.<br />
Force-ventilated motors, only available in degree of protection IP64 and<br />
IP65 (fan IP54).<br />
Cylindrical; with keyway and fitted key;<br />
Tolerance field k6<br />
H=half key balancing<br />
Tolerance R (reduced)<br />
Grade R<br />
Mounted/integrated components Mounted planetary gear for SH 28 to 132 (geared motors<br />
only available with vibration severity grade N)<br />
Cable outlet for terminal boxes Outlet direction can be selected in steps of 90°<br />
1) When using an absolute value encoder and non-ventilated or forced ventilation, the rated<br />
torque is reduced by 10 % (refer to the Table, Technical data)<br />
2) Power de-rating for temperatures > 40 °C and/or installation altitudes > 1000 m, refer to<br />
the <strong>Configuration</strong> <strong>Manual</strong> "General Section for <strong>Synchronous</strong> <strong>Motors</strong>"<br />
3) Forced ventilation cannot be used in the presence of flammable, corrosive, electrically<br />
conductive or explosive dust.<br />
4) For motors with degree of protection IP67 and IP68, since 01/2001, an M5 inner thread is<br />
provided in the cover on the NDE. This allows compressed air to be connected. The<br />
pressure in the motor should be within the range from 0.05 to 0.1 bar.<br />
The compressed air must be dry and clean. For instance, the DA300 compressed air service<br />
unit from the Heidenhain company can be used.<br />
For <strong>1FT6</strong> motors without optical encoders, it is sufficient to have<br />
a pre-filter that filters-out<br />
any foreign bodies above 3 μm.<br />
For <strong>1FT6</strong> motors with optical encoder, in addition to the pre-filter<br />
element, a fine filter is<br />
required that filters-out foreign bodies above 0.01 μm.<br />
<strong>1FT6</strong> synchronous motors<br />
1-4 <strong>Configuration</strong> <strong>Manual</strong>, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0