Table 1-5 Resistor braking for the <strong>1FT6</strong> series, shaft heights 100 to 132, non-ventilated<br />

Motor type Braking<br />

re-<br />

sistor<br />

SH 100 non-ventilated<br />

external<br />

Ropt [Ω]<br />

Average braking torque<br />

without<br />

external<br />

braking resistor<br />

Mbr rms [Nm]<br />

with<br />

external<br />

braking resistor<br />

Max.<br />

braking torque<br />

Mbr max [Nm]<br />

Motor Description<br />

1.6 Armature short-circuit braking<br />

rms braking current<br />

without<br />

external<br />

braking resistor<br />

Ibr rms [A]<br />

with<br />

external<br />

braking resistor<br />

<strong>1FT6</strong>102-8AB7⃞ 3.9 13 24 30 18 16<br />

<strong>1FT6</strong>102-8AC7⃞ 2.8 11 24 30 25 23<br />

<strong>1FT6</strong>102-8AF7⃞ 2.3 8.1 24 30 35 31<br />

<strong>1FT6</strong>102-8AH7⃞ 1.7 6.5 24 30 51 46<br />

<strong>1FT6</strong>105-8AB7⃞ 2.2 21 43 54 33 29<br />

<strong>1FT6</strong>105-8AC7⃞ 1.7 17 43 54 44 39<br />

<strong>1FT6</strong>105-8AF7⃞ 1.2 13 43 54 65 58<br />

<strong>1FT6</strong>108-8AB7⃞ 1.4 32 71 88 53 47<br />

<strong>1FT6</strong>108-8AC7⃞ 1.2 26 71 88 68 61<br />

<strong>1FT6</strong>108-8AF7⃞ 0.9 21 71 88 99 89<br />

SH 132 non-ventilated<br />

<strong>1FT6</strong>132-6AB7⃞ 1.0 1) 37 83 105 56 50<br />

<strong>1FT6</strong>132-6AC7⃞ 1.2 1) 32 83 105 75 67<br />

<strong>1FT6</strong>132-6AF7⃞ 0.8 1) 23 83 105 110 100<br />

<strong>1FT6</strong>134-6AB7⃞ 1.2 1) 47 110 140 72 65<br />

<strong>1FT6</strong>134-6AC7⃞ 0.9 1) 40 110 140 99 89<br />

<strong>1FT6</strong>136-6AB7⃞ 0.9 1) 55 130 170 91 82<br />

<strong>1FT6</strong>136-6AC7⃞ 0.8 1) 45 130 170 115 105<br />

1) When utilized to M0 (100 K), a braking resistor must be used in order to prevent partial demagnetization.<br />

When utilized to M0 (60 K), the additional braking resistor is not required.<br />

<strong>1FT6</strong> synchronous motors<br />

<strong>Configuration</strong> <strong>Manual</strong>, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0 1-17