Technical Data and Speed-Torque Diagrams<br />

3.1 Speed-torque diagrams<br />

Table 3-61 <strong>1FT6</strong>138, water cooled<br />

<strong>1FT6</strong>138<br />

Technical data Code Unit -6WB7⃞ -6WD7⃞<br />

Configuring data<br />

Rated speed<br />

Pole number<br />

Rated torque (100K)<br />

Rated current (100K)<br />

Stall torque (60K)<br />

Stall torque (100K)<br />

Stall current (60K)<br />

Stall current (100K)<br />

Moment of inertia (with brake)<br />

Moment of inertia (without brake)<br />

Optimum operating point<br />

Optimum speed<br />

Optimum power<br />

Limiting data<br />

Max. permissible speed (mech.)<br />

Max. torque<br />

Max. current 1)<br />

Physical constants<br />

Torque constant<br />

Voltage constant<br />

Winding resistance at 20° C<br />

Rotating field inductance<br />

Electrical time time constant<br />

Shaft torsional stiffness<br />

Mechanical time constant<br />

Thermal time constant<br />

Weight with brake<br />

Weight without brake<br />

nN<br />

2p<br />

MN(100K)<br />

IN (100K)<br />

M0 (60K)<br />

M0 (100K)<br />

I0 (60K)<br />

I0 (100K)<br />

Jmot<br />

Jmot<br />

nopt<br />

Popt<br />

nmax<br />

Mmax<br />

Imax<br />

kT<br />

kE<br />

Rph<br />

LD<br />

Tel<br />

ct<br />

Tmech<br />

Tth<br />

m<br />

m<br />

RPM<br />

Nm<br />

A<br />

Nm<br />

Nm<br />

A<br />

A<br />

10 –4 kgm 2<br />

10 –4 kgm 2<br />

RPM<br />

kW<br />

RPM<br />

Nm<br />

A<br />

Nm/A<br />

V/1000 RPM<br />

Ohm<br />

mH<br />

ms<br />

Nm/rad<br />

ms<br />

min<br />

kg<br />

kg<br />

1500<br />

6<br />

290<br />

112<br />

232<br />

300<br />

87<br />

112<br />

––<br />

845<br />

1500<br />

45.5<br />

3600<br />

500<br />

263<br />

2.68<br />

168<br />

0.052<br />

2<br />

38<br />

192000<br />

1.8<br />

6<br />

––<br />

137<br />

1) Observe the maximum and rated current of the drive converter<br />

2500<br />

6<br />

275<br />

162<br />

232<br />

300<br />

129<br />

167<br />

––<br />

845<br />

2500<br />

72<br />

3600<br />

500<br />

395<br />

1.80<br />

112<br />

0.023<br />

0.87<br />

38<br />

192000<br />

1.8<br />

6<br />

––<br />

137<br />

<strong>1FT6</strong> synchronous motors<br />

3-122 <strong>Configuration</strong> <strong>Manual</strong>, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0