27.12.2012 Views

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SET QIOASSIST<br />

►►<br />

SET<br />

Notes:<br />

Authorization<br />

Purpose<br />

Oper<strong>and</strong>s<br />

QIOAssist<br />

ON<br />

OFF<br />

1 Class B users only.<br />

2 Class B users only.<br />

FOR<br />

Privilege Class: B, G<br />

*<br />

(1)<br />

ALL<br />

USER<br />

(2)<br />

userid<br />

Use SET QIOASSIST to control the queue-I/O assist (QDIO performance assist for<br />

V=V guests) for a virtual machine. This interpretive-execution assist applies to<br />

devices that use the Queued Direct I/O (QDIO) architecture, HiperSockets devices,<br />

<strong>and</strong> F<strong>CP</strong> devices.<br />

On processors that support the queue-I/O assist, there is a performance benefit for<br />

I/O performed with the queued-I/O protocols. With the aid of the assist, I/O<br />

interruptions can be passed directly from the hardware to the virtual machine. In<br />

addition, certain QDIO-related instructions can be interpretively executed by the<br />

processor, without z/<strong>VM</strong>’s involvement.<br />

To use queue-I/O assist, the following are required:<br />

v The processor must support the queue-I/O assist. See the General Information<br />

Manual.<br />

v z/<strong>VM</strong> must be running in a logical partition <strong>and</strong> not as a guest.<br />

v The assist must be globally enabled with the <strong>CP</strong> SET QIOAssist ON ALL<br />

comm<strong>and</strong>.<br />

v The virtual machine must be enabled with the <strong>CP</strong> SET QIOAssist ON comm<strong>and</strong>.<br />

v The device must not be attached to the virtual machine with the NOQIOAssist<br />

option of the <strong>CP</strong> ATTACH comm<strong>and</strong> or the system-directory DEDICATE<br />

statement.<br />

v The virtual machine must not be using the <strong>CP</strong> TRACE comm<strong>and</strong>.<br />

SET QIOASSIST<br />

ON, OFF<br />

turns the queue-I/O assist on or off for a virtual machine.<br />

ALL<br />

enables or disables eligibility for all virtual machines to use the queue-I/O<br />

assist, independent of the individual settings for each user. The individual<br />

►◄<br />

Chapter 2. <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> 1329

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!