XLINK<br />

Authorization<br />

Purpose<br />

Usage Notes<br />

Responses<br />

Messages<br />

Privilege Class: A, B<br />

H<strong>CP</strong>0023E Volid missing or invalid<br />

Use the XLINK family of comm<strong>and</strong>s to perform the following cross system extension<br />

(CSE) functions:<br />

XLINK CHECK<br />

Use XLINK CHECK to determine whether one or more volumes are under<br />

cross system link control.<br />

XLINK FINDTAB<br />

Use XLINK FINDTAB to attempt to verify that the CSE system table<br />

matches the date <strong>and</strong> time stamp in the <strong>CP</strong> table.<br />

XLINK RESET<br />

Use XLINK RESET to free links held by a failed system.<br />

1. Documentation for the following <strong>CP</strong> utilities may be found in the <strong>CP</strong> <strong>Utilities</strong><br />

section of this book:<br />

XLINK DISPLAY<br />

Use XLINK DISPLAY to display link indicators in the map records of all<br />

systems on a particular device.<br />

XLINK FORMAT<br />

Use XLINK FORMAT to prepare DASD for sharing by initializing the<br />

CSE track on the specified DASD volume.<br />

Note: The following responses <strong>and</strong> messages may be issued for XLINK CHECK,<br />

XLINK FINDTAB, or XLINK RESET.<br />

H<strong>CP</strong>2883I Volume volidn is not controlled by CSE LINK.<br />

H<strong>CP</strong>2884I Volume volidn is controlled by CSE LINK.<br />

H<strong>CP</strong>2886D Are you ready for XLINK RESET of<br />

system sysname, volume volidn?<br />

Enter YES or NO:<br />

H<strong>CP</strong>2887I XLINK RESET complete.<br />

H<strong>CP</strong>2888I XLINK RESET ignored.<br />

H<strong>CP</strong>0026E Oper<strong>and</strong> missing or invalid<br />

H<strong>CP</strong>2892I WARNING! XLINK RESET must be used with<br />

extreme caution. Improper use will cause<br />

loss of minidisk data.<br />

XLINK<br />

H<strong>CP</strong>2881E XLINK RESET is not allowed. There is<br />

no CSE LINK control on this system.<br />

Chapter 2. <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> 1745