27.12.2012 Views

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

z/VM: CP Commands and Utilities Reference - z/VM - IBM

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

LOCATE RDEV<br />

Messages<br />

Note: If there is an asterisk (*) in a response field, there is no information for that<br />

field.<br />

Dev shows the real device number.<br />

RDEV shows the address of the corresponding real device block.<br />

<strong>CP</strong>VOL<br />

shows the address of the system volume list entry.<br />

VEXBK<br />

shows the address of the volume extent block, which contains information<br />

on all the extents on a <strong>CP</strong>-owned volume.<br />

RSPBK<br />

shows the address of the real spool device block.<br />

SPFBK<br />

shows the address of the spool file control block.<br />

Response 2:<br />

To locate the address of the real device block for the specified device, enter:<br />

locate 0100<br />

RDEV<br />

07B1A3C8<br />

Ready;<br />

Response 3:<br />

To locate the address of the real device block for the specified device, enter:<br />

locate 0a01<br />

RDEV <strong>CP</strong>VOL VEXBK<br />

07AF05A8<br />

Ready;<br />

07B1CB30 07B6A02C<br />

It also shows there are two control blocks (<strong>CP</strong>VOL <strong>and</strong> VEXBK) associated with this<br />

real device block, <strong>and</strong> it gives their addresses.<br />

Response 4:<br />

To locate the address of the real device block for the specified device, enter:<br />

locate 0e0e<br />

RDEV RSPBK SPFBK<br />

07ADC1E8 07AA40E8 0760BB68<br />

Ready;<br />

It also shows there are two control blocks (RSPBK <strong>and</strong> SPFBK) associated with this<br />

real device block, <strong>and</strong> it gives their addresses.<br />

H<strong>CP</strong>003E Invalid option - comm<strong>and</strong> contains<br />

extra option(s) starting with option<br />

H<strong>CP</strong>009E Invalid range - range<br />

H<strong>CP</strong>021E A real device number was not<br />

specified or it is invalid.<br />

544 z/<strong>VM</strong>: <strong>CP</strong> <strong>Comm<strong>and</strong>s</strong> <strong>and</strong> <strong>Utilities</strong> <strong>Reference</strong><br />

H<strong>CP</strong>026E Oper<strong>and</strong> missing or invalid<br />

H<strong>CP</strong>6720I No items found to satisfy selection<br />

criteria.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!