CALCulate Subsystem (CATV, K20) R&S <strong>ZVL</strong>‑<strong>K1</strong><br />

CALC:DTV:LIM:RES:MERR:UPP?<br />

Per<strong>for</strong>ms an upper limit check <strong>for</strong> <strong>the</strong> root mean square value of <strong>the</strong> modulation error rate.<br />

Characteristics<br />

RST value: –<br />

SCPI: device–specific<br />

Mode<br />

CATV<br />

CALCulate:DTV:LIMit:RESult:PJITter[:UPPer]?<br />

This command per<strong>for</strong>ms an upper limit check <strong>for</strong> <strong>the</strong> phase jitter in <strong>the</strong> Modulation Errors<br />

measurement.<br />

This command is a query and <strong>the</strong>re<strong>for</strong>e has no *RST value.<br />

Example<br />

CALC:DTV:LIM:PJIT 1<br />

Sets <strong>the</strong> upper limit <strong>for</strong> <strong>the</strong> phase jitter to 1 deg.<br />

INIT;*WAI<br />

Starts a new measurement and waits <strong>for</strong> <strong>the</strong> sweep end.<br />

CALC:DTV:LIM:RES:PJIT?<br />

Per<strong>for</strong>ms an upper limit check <strong>for</strong> <strong>the</strong> phase jitter.<br />

Characteristics<br />

RST value: –<br />

SCPI: device–specific<br />

Mode<br />

CATV<br />

CALCulate:DTV:LIMit:RESult:QERRor:LOWer?<br />

This command per<strong>for</strong>ms a lower limit check <strong>for</strong> <strong>the</strong> quadrature error in <strong>the</strong> Modulation Errors<br />

measurement.<br />

This command is a query and <strong>the</strong>re<strong>for</strong>e has no *RST value.<br />

Example<br />

CALC:DTV:LIM:QERR:LOW 10<br />

Sets <strong>the</strong> lower limit <strong>for</strong> <strong>the</strong> quadrature error to 10 deg.<br />

INIT;*WAI<br />

Starts a new measurement and waits <strong>for</strong> <strong>the</strong> sweep end.<br />

CALC:DTV:LIM:RES:QERR:LOW?<br />

Per<strong>for</strong>ms a lower limit check <strong>for</strong> <strong>the</strong> quadrature error.<br />

Characteristics<br />

RST value: –<br />

SCPI: device–specific<br />