28.12.2012 Views

Software Manual for the R&S ZVL-K1 - Rohde & Schwarz

Software Manual for the R&S ZVL-K1 - Rohde & Schwarz

Software Manual for the R&S ZVL-K1 - Rohde & Schwarz

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

WiMAX, WiBro Measurements (Option K93) R&S <strong>ZVL</strong>-<strong>K1</strong><br />

– Spectrum FFT (see Spectrum FFT softkey)<br />

– Constellation vs Symbol (see Constell vs Symbol/Carrier softkey)<br />

– Constellation vs Carrier (IEEE 802.16–2004 OFDM only, see Constell vs Symbol/Carrier<br />

softkey)<br />

– Conditional Cumulative Distribution Function (see CCDF softkey)<br />

– Bit Stream (see Bitstream softkey)<br />

frequency sweep measurements<br />

– Spectrum Mask (see Spectrum IEEE/ETSI softkey)<br />

– Spectrum ACP/ACPR (see ACPR Abs/Rel softkey)<br />

For current restrictions refer to Current restrictions to <strong>the</strong> IEEE 802.16e–2005 OFDMA/WiBro signal to<br />

be analyzed.<br />

The measurement result display is divided into two panes:<br />

Measurement settings<br />

Result displays<br />

The results can be displayed in <strong>for</strong>m of a list or a graph (see also Display List/Graph softkey).<br />

– Result summary list<br />

– Result display graph<br />

Current restrictions to <strong>the</strong> IEEE 802.16e–2005 OFDMA/WiBro signal to be analyzed<br />

standard<br />

– IEEE 16–2004/Cor1–2005, IEEE 802.16e–2005, OFDMA Physical Layer Mode, 1 October<br />

2004/28 February 2006<br />

– IEEE 16–2004/Cor1–2005, IEEE 802.16e–2005 based WiBro<br />

FFT sizes<br />

The FFT sizes 128, 512, 1024 and 2048 are supported.<br />

subframes<br />

– Ei<strong>the</strong>r a DL subframe or a UL subframe can be analyzed at one point in time.<br />

– One DL–PUSC zone per DL subframe is supported.<br />

– One DL–FUSC zone immediately following <strong>the</strong> first mandatory DL–PUSC zone is supported<br />

(DL subframe).<br />

– One UL–PUSC zone per UL subframe is supported.<br />

– The subframes have to be separated by sufficient power off gaps.<br />

segments<br />

The first mandatory DL–PUSC zone must contain exclusively one segment. The assignment of<br />

subchannel groups to this segment is not restricted.<br />

symbols<br />

The signal to be analyzed must contain at least two OFDMA data symbols. More OFDMA data<br />

symbols will improve <strong>the</strong> accuracy of <strong>the</strong> measurement results.<br />

burst<br />

1303.6573.42 3.416 E-5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!