28.12.2012 Views

Software Manual for the R&S ZVL-K1 - Rohde & Schwarz

Software Manual for the R&S ZVL-K1 - Rohde & Schwarz

Software Manual for the R&S ZVL-K1 - Rohde & Schwarz

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CALCulate:MARKer Subsystem (WiMAX, K93) R&S <strong>ZVL</strong>‑<strong>K1</strong><br />

CALCulate:MARKer:FUNCtion Subsystem (WiMAX, K93)<br />

The measurement window is selected by CALCulate 1 (screen A) or 2 (screen B).<br />

Commands of <strong>the</strong> CALCulate:MARKer:FUNCtion Subsystem<br />

– CALCulate:MARKer:FUNCtion:POWer:RESult[:CURRent]?<br />

– CALCulate:MARKer:FUNCtion:POWer:RESult:MAXHold?<br />

– CALCulate:MARKer:FUNCtion:ZOOM<br />

CALCulate:MARKer:FUNCtion:POWer:RESult[:CURRent]?<br />

This command queries <strong>the</strong> current result values of <strong>the</strong> adjacent channel power measurement.<br />

An ACPR (Adjacent channel power relative) measurement must have previously been run to<br />

provide <strong>the</strong> summary data.<br />

The numeric suffix at CALCulate specifies <strong>the</strong> measurement window.<br />

This command is only a query and <strong>the</strong>re<strong>for</strong>e has no *RST value.<br />

Results are output separated by commas. Adjacent channel power values are output in dB. The<br />

order is as follows:<br />

– Power of main channel<br />

– Power of lower adjacent channel<br />

– Power of upper adjacent channel<br />

– Power of lower alternate adjacent channel 1<br />

– Power of upper alternate adjacent channel 1<br />

– Power of lower alternate adjacent channel 2<br />

– Power of upper alternate adjacent channel 2<br />

– Power of lower alternate adjacent channel 3<br />

– Power of upper alternate adjacent channel 3<br />

– Power of lower alternate adjacent channel 4<br />

– Power of upper alternate adjacent channel 4<br />

Example<br />

CALC2:MARK:FUNC:POW:RES?<br />

Characteristics<br />

RST value: –<br />

SCPI: device–specific<br />

Mode<br />

OFDM, OFDMA/WiBro<br />

CALCulate:MARKer:FUNCtion:POWer:RESult:MAXHold?<br />

This command queries <strong>the</strong> maximum result values of <strong>the</strong> adjacent channel power<br />

measurement. An ACPR (Adjacent channel power relative) measurement must have previously<br />

been run with more than one sweep to provide <strong>the</strong> summary data.<br />

For details on <strong>the</strong> result output refer to<br />

CALCulate:MARKer:FUNCtion:POWer:RESult[:CURRent]?<br />

The numeric suffix at CALCulate specifies <strong>the</strong> measurement window.<br />

1303.6573.42 4.758 E-5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!