28.12.2012 Views

Software Manual for the R&S ZVL-K1 - Rohde & Schwarz

Software Manual for the R&S ZVL-K1 - Rohde & Schwarz

Software Manual for the R&S ZVL-K1 - Rohde & Schwarz

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

R&S <strong>ZVL</strong>-<strong>K1</strong> Bluetooth Measurements (Option K8)<br />

Ref Level Offset<br />

For details refer to <strong>the</strong> Ref Level Offset softkey in <strong>the</strong> amplitude menu of <strong>the</strong> base unit.<br />

Ref Level Position<br />

For details refer to <strong>the</strong> Ref Level Position softkey in <strong>the</strong> amplitude menu of <strong>the</strong> base unit.<br />

Input 50 Ω / 75 Ω<br />

For details refer to <strong>the</strong> Input 50 Ω / 75 Ω softkey in <strong>the</strong> amplitude menu of <strong>the</strong> base unit.<br />

Softkeys of <strong>the</strong> bandwidth menu (Bluetooth mode)<br />

The following table shows all softkeys available in <strong>the</strong> bandwidth menu in Bluetooth mode (PWR BW<br />

key). It is possible that your instrument configuration does not provide all softkeys. If a softkey is only<br />

available with a special option, model or (measurement) mode, this in<strong>for</strong>mation is delivered in <strong>the</strong><br />

corresponding softkey description.<br />

Command<br />

Meas Time <strong>Manual</strong><br />

Meas Time Auto<br />

Sweeptime <strong>Manual</strong><br />

Sweeptime Auto<br />

Res BW <strong>Manual</strong><br />

Res BW Auto<br />

Video BW <strong>Manual</strong><br />

Video BW Auto<br />

Filter Type<br />

Meas Filter<br />

Meas Time <strong>Manual</strong><br />

(Output Power, Modulation Char, Init Carr Freq Tol, Carr Freq Drift, Rel TX Power, Carr Freq<br />

Stability, Diff Phase)<br />

Opens an edit dialog box to enter <strong>the</strong> measurement time. The valid value range is 1 µs to<br />

(400001 / points per symbol) µs.<br />

� Remote: CONF:BTO:SWE:TIME 10MS<br />

Meas Time Auto<br />

(Output Power, Modulation Char, Init Carr Freq Tol, Carr Freq Drift, Rel TX Power, Carr Freq<br />

Stability, Diff Phase)<br />

Activates <strong>the</strong> automatic calculation of <strong>the</strong> measurement time. The automatic sweep time<br />

corresponds to <strong>the</strong> settings defined in <strong>the</strong> RF Test Specification. By default, <strong>the</strong> automatic<br />

sweep time calculation is activated.<br />

� Remote: CONF:BTO:SWE:TIME:AUTO ON<br />

1303.6573.42 3.157 E-5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!