R&S <strong>ZVL</strong> Instrument Setup and Interface Configuration - SETUP Key<br />

Menu Command Submenu / Command Submenu / Command Command<br />

More �<br />

Soft Frontpanel<br />

Firmware Update � Firmware Update<br />

Option Licenses � Install Option<br />

Shutdown Off/Standby<br />

System Info � Hardware Info<br />

Versions+Options<br />

System Messages<br />

Clear All Messages<br />

Service � Input RF/Cal/TG<br />

Reference Int/Ext<br />

Comb Frequency<br />

Reset Password<br />

Selftest<br />

Selftest Results<br />

Password<br />

Service Function<br />

Switches between <strong>the</strong> internal and external reference signal source. The default setting is<br />

internal reference. It is important, that <strong>the</strong> external reference signal is deactivated when<br />

switching from external to internal reference to avoid interactions.<br />

If <strong>the</strong> reference signal is missing when switching to external reference, <strong>the</strong> message EXREF is<br />

displayed to indicate that no synchronization is per<strong>for</strong>med.<br />

The R&S <strong>ZVL</strong> can use <strong>the</strong> internal reference source or an external reference source as<br />

frequency standard from which all internal oscillators are derived. A 10 MHz crystal oscillator is<br />

used as internal reference source. In <strong>the</strong> external reference setting, all internal oscillators of <strong>the</strong><br />

R&S <strong>ZVL</strong> are synchronized to <strong>the</strong> external reference frequency (also 10 MHz). For details on<br />

connectors refer to <strong>the</strong> Quick Start Guide, chapter 1 "Front and Rear Panel".<br />

� Remote: ROSC:SOUR INT<br />

Transducer<br />

Opens <strong>the</strong> Select Transducer dialog box and a submenu to activate or deactivate defined<br />

transducer factors, to generate new transducer factors or to edit existing ones.<br />

In <strong>the</strong> Select Transducer dialog box, a transducer factor can be edited, deleted or copied, if<br />

selected, using <strong>the</strong> corresponding softkeys. The default directory, in which <strong>the</strong> transducer factors<br />

are saved, is displayed (C:\R_S\INSTR\TRD; <strong>the</strong> extension of transducer factor files is *.TDF).<br />

Subdirectories can be added or deleted via <strong>the</strong> file manager. They are displayed or hidden using<br />

<strong>the</strong> arrow keys or <strong>the</strong> Show Directory softkey / Hide Directory button.<br />

Two different directory views are possible: If <strong>the</strong> Show all option is activated, all transducer<br />

factors in <strong>the</strong> directory are displayed. If <strong>the</strong> Show compatible option is activated, only <strong>the</strong><br />

compatible transducer factors in <strong>the</strong> directory are displayed.<br />

For details on transducer factors refer to chapter "Advanced Measurement Examples".<br />

1303.6573.42 4.467 E-6