TRACe Subsystem (WLAN, K91 / K91n) R&S <strong>ZVL</strong>‑<strong>K1</strong><br />

TRACe Subsystem (WLAN, K91 / K91n)<br />

The TRACe subsystem controls access to <strong>the</strong> instrument's internal trace memory.<br />

Commands of <strong>the</strong> TRACe Subsystem<br />

– TRACe[:DATA]<br />

– TRACe:IQ:DATA:MEMory?<br />

– TRACe:IQ:SRATe<br />

Fur<strong>the</strong>r in<strong>for</strong>mation<br />

– IQ Measurements<br />

– Constellation vs Symbol<br />

– Constellation vs Carrier<br />

– Power vs Time – Full Burst and Rising /Falling Data<br />

– Spectrum Flatness<br />

– Spectrum FFT<br />

– Statistics Bitstream data<br />

– Statistics CCDF – Complementary cumulative distribution function<br />

– Statistics Signal Field data<br />

– EVM vs Carrier<br />

– EVM vs Symbol<br />

– Error vs Preamble<br />

– Frequency Sweep Measurements<br />

– Spectrum Mask<br />

– Spectrum ACPR<br />

IQ Measurements<br />

There are a number of measurements that can be per<strong>for</strong>med in IQ mode. No data will be returned <strong>for</strong><br />

any of <strong>the</strong> following measurements, should it be requested, until such time as a measurement<br />

belonging to <strong>the</strong> IQ group has been previously run.<br />

Running a frequency sweep measurement <strong>for</strong> example, Spectrum Mask, will not generate results <strong>for</strong><br />

this measurement group.<br />

Constellation vs Symbol<br />

This measurement represents I and Q data. For IEEE 802.11a, j and n <strong>the</strong> data will be returned as a<br />

repeating array of interleaved I and Q data in groups of selected carriers, until all <strong>the</strong> data is exhausted.<br />

For IEEE 802.11b <strong>the</strong> data will be returned as a repeating array of interleaved I and Q data in symbol<br />

order until all <strong>the</strong> data is exhausted.<br />

Each I and Q point will be returned in floating point <strong>for</strong>mat. TRACE1 is used <strong>for</strong> this measurement<br />

results.<br />

IEEE 802.11a, j and n only<br />

If "All Carriers'' is selected, it will return 52 per of I and Q data per symbol.<br />

1303.6573.42 4.724 E-5