R&S <strong>ZVL</strong> Instrument Setup and Interface Configuration - SETUP Key<br />

Edit Value<br />

Sets <strong>the</strong> focus to enter positions and values as frequency/level pairs. The entered data are also<br />

displayed graphically. Using <strong>the</strong> Shift x or Shift y button, all entered values can be shifted in x<br />

or y direction.<br />

This softkey is available from firmware version 1.10.<br />

� Remote: CORR:TRAN:DATA ,<br />

Interpolation Lin/Log<br />

Sets <strong>the</strong> scaling of <strong>the</strong> x-axis to linear or logarithmic.<br />

This softkey is available from firmware version 1.10.<br />

� Remote: CORR:TRAN:SCAL LIN|LOG<br />

Save Factor<br />

Saves <strong>the</strong> changed factor to a file on <strong>the</strong> internal flash disk. If a transducer factor with <strong>the</strong> same<br />

name already exists, a confirmation query is displayed. If <strong>the</strong> new factor is active, <strong>the</strong> new<br />

values are immediately applied.<br />

This softkey is available from firmware version 1.10.<br />

� Remote: In remote control, <strong>the</strong> save operation is per<strong>for</strong>med automatically after <strong>the</strong> definition of <strong>the</strong><br />

reference values.<br />

New<br />

Opens <strong>the</strong> Edit Transducer dialog box to enter data <strong>for</strong> a new factor.<br />

This softkey is available from firmware version 1.10.<br />

Copy to<br />

Delete<br />

Opens <strong>the</strong> Edit Transducer dialog box to copy <strong>the</strong> selected factor.<br />

This softkey is available from firmware version 1.10.<br />

Deletes <strong>the</strong> selected factor after confirmation.<br />

This softkey is available from firmware version 1.10.<br />

� Remote: CORR:TRAN DEL<br />

Ref Level Adjust Man/Auto<br />

Activates or deactivates <strong>the</strong> automatic adjustment of <strong>the</strong> reference level to <strong>the</strong> selected<br />

transducer factor.<br />

Auto Activates <strong>the</strong> automatic adjustment.<br />

Man Deactivates <strong>the</strong> automatic adjustment. Adjust <strong>the</strong> reference level via <strong>the</strong> amplitude<br />

menu.<br />

1303.6573.42 4.469 E-6