Using Marker and Delta Marker R&S <strong>ZVL</strong>-<strong>K1</strong><br />

REM ************************************************************************<br />

Public Sub TOI()<br />

result$ = Space$(100)<br />

'––––––––– R&S <strong>ZVL</strong>-<strong>K1</strong> default setting ––––––––––––––––––––––––––––––––––––––<br />

––<br />

CALL SetupStatusReg 'Set status registers<br />

CALL InstrWrite(analyzer,"*RST") 'Reset instrument<br />

CALL InstrWrite(analyzer,"INIT:CONT OFF") 'Single sweep<br />

CALL InstrWrite(analyzer,"SYST:DISP:UPD ON")<br />

'ON: display on<br />

'OFF: off<br />

'––––––––– Set frequency –––––––––––––––––––––––––––––––––––––––––––––––––––<br />

CALL InstrWrite(analyzer,"FREQ:STARt 85MHz;STOP 125 MHz")<br />

'Span<br />

'––––––––– Set level –––––––––––––––––––––––––––––––––––––––––––––––––––––––<br />

CALL InstrWrite(analyzer,"DISP:WIND:TRAC:Y:RLEV –20dBm")<br />

'Reference level<br />

CALL InstrWrite(analyzer,"INIT;*WAI") 'Per<strong>for</strong>m sweep with sync<br />

'––––––––– TOI measurement –––––––––––––––––––––––––––––––––––––––––––––––––<br />

CALL InstrWrite(analyzer,"CALC:MARK:PEXC 6DB")<br />

'Peak excursion<br />

CALL InstrWrite(analyzer,"CALC:MARK:FUNC:TOI ON")<br />

'Switch on TOI measurement<br />

CALL InstrWrite(analyzer,"CALC:MARK:FUNC:TOI:RES?")<br />

'and read out results<br />

CALL InstrRead(analyzer,result$)<br />

'––––––––– Read out result ––––––––––––––––––––––––––––––––––––––––––––––––<br />

Print "TOI [dBm]: ";result$<br />

END SUB<br />

REM ************************************************************************<br />

Measuring <strong>the</strong> AM Modulation Depth<br />

The example below is based on an AM–modulated signal at 100 MHz with <strong>the</strong> following characteristics:<br />

Carrier signal level: –30 dBm<br />

AF frequency: 100 kHz<br />

Modulation depth: 50 %<br />

The default setting of <strong>the</strong> analyzer <strong>for</strong> measurements can be used <strong>for</strong> <strong>the</strong> measurements described<br />

below (SetupInstrument).<br />

REM ************************************************************************<br />

Public Sub AMMod()<br />

result$ = Space$(100)<br />

CALL SetupInstrument 'Default setting<br />

CALL InstrWrite(analyzer,"BAND:RES 30kHz") 'Set appropriate RBW<br />

1303.6573.42 5.8 E-5