JUMPER WIRES<br />
36<br />
AP PLI CA TION<br />
For fixed in stal la tion in neon lu mi naires.<br />
Maxi mum per mis si ble tem pera ture of con duc tor:<br />
- in con tinu ous use +70 °C<br />
- in a short cir cuit (max. 5 s) +160 °C<br />
Low est rec om mended<br />
han dling tem pera ture: -15 °C<br />
Mini mum rec om mended<br />
bend ing ra dius:<br />
- dur ing in stal la tion 8xD<br />
- in a fi nal in stal la tion if bent only once 4xD<br />
CON STRUC TION<br />
Con duc tor An nealed cop per wires,<br />
str<strong>and</strong>ed flexi ble<br />
Plas tic- in su la ted con duc tor<br />
MVJ 8 kV<br />
Fle xib le con duc tor<br />
RATED VOLT AGE<br />
U o /U = 8/8 kV<br />
STAN DARD<br />
SFS 5680<br />
Cross-section of conductors<br />
<strong>and</strong> colour mm² 1,5 KE<br />
EAN code (SSTL code) 64 100+ 04 201 03-9<br />
Nominal overall diameter mm 6,7<br />
Total weight kg/km 56<br />
Direct current resistance of<br />
conductor at +20 °C max. Ω/km 13,3<br />
St<strong>and</strong>ard delivery length<br />
coil m 100<br />
Self- extinguishing IEC 332-1<br />
In su la tion PVC, yel low