DATA CA BLES<br />

70<br />

N<br />

Data cab le, category 5, UTP<br />

UC 300 24 4P / UC 300 D 24 2 x 4P<br />

AP PLI CA TIONS<br />

— Fixed in door — Eth er net 100 Mbit/s<br />

in stal la tions — To ken Ring 4/16 Mbit/s<br />

— CDDI — Tele phone net works<br />

— TP- PMD — ISDN<br />

— ATM — Ge neric ca bling sys tem<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- during operation 5xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion:<br />

UC 300 24 4P 80 N<br />

UC 300 D 24 2 x 4P 160 N<br />

STAN DARDS<br />

UC 300 24 4P is available as halogenfree UC 300 D 24 2 x 4P- FRNC-B/C version.<br />

EN 50173; prEN 50288-3-1<br />

ISO/IEC 11801 2 rd ed<br />

TIA/EIA 568-A<br />

ISO 8802.3/IEEE 802.3 100 base T<br />

IDEN TI FI CA TION<br />

Pair Col our code Pair Col our code<br />

1 white/blue 3 white/green<br />

2 white/orange 4 white/brown<br />

On the a-wire there is a stripe of the same colour as<br />

the corresponding b-wire.<br />

The ca ble fulfils the fire con di tion re quire ments of<br />

IEC 332-1.