DATA CA BLES<br />
68<br />
Data cab le, category 5, FTP<br />
UC 300 S 24 4P / UC 300 DS 24 2 x 4P<br />
N<br />
AP PLI CA TIONS<br />
— Fixed in door — Eth er net 100 Mbit/s<br />
in stal la tions — To ken Ring 4/16 Mbit/s<br />
— CDDI — Tele phone net works<br />
— TP- PMD — ISDN<br />
— ATM — Ge neric ca bling sys tem<br />
Maxi mum ambient tem pera ture:<br />
- in operation +70 °C<br />
Low est rec om mended installation<br />
tem pera ture: –5 °C<br />
Mini mum rec om mended bend ing ra dius:<br />
- dur ing in stal la tion 10xD<br />
- during operation 5xD<br />
Maxi mum per mis si ble ten sile stress<br />
dur ing in stal la tion:<br />
UC 300 S 24 4P 80 N<br />
UC 300 DS 24 2 x 4P 160 N<br />
STAN DARDS<br />
EN 50173; prEN 50288-3-1<br />
ISO/IEC 11801 2 rd ed<br />
TIA/EIA 568-A<br />
ISO 8802.3/IEEE 802.3 100 base T<br />
IDEN TI FI CA TION<br />
UC 300 S 24 4P is available as halogenfree UC 300 DS 24 2 x 4P- FRNC-B/C version.<br />
Pair Col our code Pair Col our code<br />
1 white/blue 3 white/green<br />
2 white/orange 4 white/brown<br />
On the a-wire there is a stripe of the same colour as<br />
the corresponding b-wire.<br />
The ca ble fulfils the fire con di tion re quire ments of<br />
IEC 332-1.