DATA CA BLES<br />
Data cab le, category 6, STP, Patented<br />
UC 400 S 23/1 4P/UC 400 DS 23/1 2x4P<br />
CON STRUC TION<br />
Conductor Copper wire, d=0,56 mm<br />
Insulation PE<br />
Unit Twisted pair<br />
CA BLE SIZES<br />
Type UC 400 S 23/1 4P UC 400 DS 23/1 2x4P<br />
EAN code (SSTL code) 64 100+ 02 640 75 02 640 76<br />
Nomi nal di ame ters mm 6,5 6,5/13,0<br />
Mass kg/km 41 82<br />
De liv ery length m 500 500<br />
ELEC TRI CAL PROP ER TIES 20 °C<br />
Loop re sis tance, max Ω/km 176<br />
In su la tion re sis tance, min GΩ x km 2<br />
Nomi nal mu tual ca paci tance nF/km 48<br />
Maxi mum ca paci tance<br />
un bal ance, pair to ground pF/km ≤1500<br />
Nomi nal im ped ance Ω ƒ =1 - 100 MHz 100 ± 15<br />
Trans fer imped ance, max mΩ/m 100<br />
Ve loc ity fac tor 0,78<br />
Maxi mum volt age V 75<br />
TRANSMISSION CHARACTERISTICS ACC. TO CATEGORY 6 (at 20 °C)<br />
Fre quency<br />
MHz<br />
1<br />
4<br />
10<br />
16<br />
20<br />
31,2<br />
62,5<br />
100<br />
125<br />
155,5<br />
175<br />
200<br />
250<br />
300<br />
400<br />
Attenuation<br />
(dB/100 m)<br />
NEXT<br />
(dB)<br />
PS-NEXT<br />
(dB)<br />
ACR<br />
(dB/100 m)<br />
PS-ACR<br />
(dB/100 m)<br />
ELFEXT<br />
(dB/100 m)<br />
PS-ELFEXT<br />
(dB/100 m)<br />
max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />
2,2<br />
3,8<br />
6,0<br />
7,6<br />
8,5<br />
10,7<br />
15,5<br />
19,9<br />
22,5<br />
25,4<br />
27,1<br />
29,2<br />
33,0<br />
2<br />
3,8<br />
6,0<br />
7,6<br />
8,5<br />
10,7<br />
15,1<br />
19,1<br />
21,3<br />
23,8<br />
25,3<br />
27,0<br />
32,6<br />
35,7<br />
41,2<br />
74<br />
65<br />
59<br />
56<br />
55<br />
52<br />
47<br />
44<br />
43<br />
42<br />
41<br />
40<br />
38<br />
87<br />
78<br />
72<br />
69<br />
68<br />
65<br />
60<br />
57<br />
56<br />
54<br />
53<br />
53<br />
51<br />
50<br />
48<br />
71<br />
62<br />
56<br />
53<br />
52<br />
49<br />
44<br />
41<br />
40<br />
39<br />
38<br />
37<br />
35<br />
84<br />
75<br />
69<br />
66<br />
65<br />
62<br />
57<br />
54<br />
53<br />
51<br />
50<br />
50<br />
48<br />
47<br />
45<br />
Earth wire Tinned copper<br />
Screen Special wrapping of Al laminated foil<br />
Sheath Blue PVC<br />
71,8<br />
61,2<br />
53,0<br />
48,4<br />
46,5<br />
41,3<br />
31,5<br />
24,1<br />
20,5<br />
16,6<br />
13,9<br />
10,8<br />
5,0<br />
85,0<br />
74,2<br />
66,0<br />
61,3<br />
59,0<br />
54,0<br />
45,0<br />
37,9<br />
34,2<br />
30,3<br />
28,1<br />
25,5<br />
18,5<br />
14,2<br />
6,8<br />
68,8<br />
58,2<br />
50,0<br />
45,4<br />
43,5<br />
38,3<br />
28,5<br />
21,1<br />
17,5<br />
13,6<br />
10,9<br />
7,8<br />
2,0<br />
82,0<br />
71,2<br />
63,0<br />
58,3<br />
56,0<br />
51,0<br />
42,0<br />
34,9<br />
31,2<br />
27,3<br />
25,1<br />
22,5<br />
15,5<br />
11,2<br />
3,8<br />
67<br />
55<br />
47<br />
43<br />
41<br />
37<br />
31<br />
27<br />
25<br />
23<br />
22<br />
21<br />
19<br />
75<br />
75<br />
75<br />
71<br />
69<br />
65<br />
59<br />
55<br />
53<br />
51<br />
50<br />
49<br />
47<br />
45<br />
53<br />
64<br />
52<br />
44<br />
40<br />
38<br />
34<br />
28<br />
24<br />
22<br />
20<br />
19<br />
18<br />
16<br />
72<br />
72<br />
72<br />
68<br />
66<br />
62<br />
56<br />
52<br />
50<br />
48<br />
47<br />
46<br />
44<br />
42<br />
40<br />
Return<br />
loss<br />
(dB)<br />
23<br />
23<br />
23<br />
23<br />
23<br />
23<br />
23<br />
23<br />
21<br />
21<br />
21<br />
21<br />
19<br />
The right to al tera tions re served.<br />
73