DATA CA BLES<br />
84<br />
AP PLI CA TIONS<br />
— Fixed in door — To ken Ring 4/16 Mbit/s<br />
in stal la tions — Tele phone net works<br />
— Eth er net 10 Mbit/s — RS 232/422/423<br />
Maxi mum ambient tem pera ture:<br />
- in operation +70 °C<br />
Low est rec om mended installation<br />
tem pera ture: –5 °C<br />
Mini mum rec om mended bend ing ra dius:<br />
- dur ing in stal la tion 10xD<br />
- during operation 15xD<br />
Data <strong>and</strong> instru men ta ti on cab le<br />
DA TA JA MAK<br />
DA TA JA MAK is available as halo gen free, DATAJAMAK- HF ver sion.<br />
STAN DARDS<br />
ISO 8802.3/IEEE 802.3 10 base T<br />
IDEN TI FI CA TION<br />
a- conductor is white <strong>and</strong> b- conductor is or ange<br />
The ca ble fufils the fire con di tion re quire ments of<br />
IEC 332-1.