IN STRU MEN TA TION CA BLES<br />

46<br />

AP PLI CA TIONS<br />

— Fixed in door — Proc ess con trol<br />

in stal la tions — Audio sys tems<br />

— Auto ma tion — Suit able <strong>for</strong> Maxi<br />

— In stru men ta tion Ter mipoint con nec tions<br />

Suit able spe cially <strong>for</strong> digi tal <strong>and</strong> low level analog sig nal<br />

trans mis sion. The con struc tion gives an ex cel lent<br />

pro tec tion against elec tro mag netic in ter fer en cies.<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

CON STRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PE<br />

Unit Twisted <strong>and</strong> in di vidu ally with<br />

plas tic-alu min ium tape shielded pair,<br />

earth con duc tor <strong>and</strong> a number tape<br />

CA BLE SIZES<br />

Instru men ta ti on cab le<br />

JA MAK ®<br />

IDEN TI FI CA TION<br />

Units marked with numbers,<br />

a- conductors are blue <strong>and</strong> b- conductors are red.<br />

The cable ful fils the fire con di tion re quire ments of<br />

IEC 332-1 (Flame re tar dant).<br />

Shield Plas tic-alu min ium tape with earth<br />

con duc tor<br />

Sheath Grey LINYL- PVC<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2 2 x( 2+1) x 0,5 4 x (2+1) x 0,5 8 x (2+1) x 0,5 12 x (2+1) x 0,5 24 x (2+1) x 0,5 48 x (2+1) x 0,5<br />

EAN code (SSTL code) 64 100+ 02 642 52-0 02 642 54-4 02 642 58-2 02 642 62-9 02 642 64-3 02 642 68-1<br />

Nomi nal di ame ter mm 8,0 9,5 13,0 15,0 21,0 29,0<br />

Mass kg/km 70 110 200 280 530 1000<br />

De liv ery length m 1000/200 1000/200 1000 1000 1000 500<br />

ELEC TRI CAL PROP ER TIES, 20 °C<br />

Maxi mum loop re sis tance Ω/km 81<br />

Nomi nal mu tual ca paci tance<br />

(800 Hz) nF/km 85<br />

Im ped ance, 10 MHz Ω 70 ± 10 %<br />

Mini mum in su la tion re sis tance GΩ x km 2<br />

Ve loc ity fac tor 0,66<br />

Maxi mum volt age V 75<br />

Nomi nal at tenua tion dB/100 m<br />

fre quency 9,6 kHz<br />

fre quency 19,2 kHz<br />

fre quency 64 kHz<br />

fre quency 100 kHz<br />

fre quency 200 kHz<br />

fre quency 1,0 MHz<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

JA MAK is also available as halo gen free (JAMAK- HF) <strong>and</strong> more effectively shielded (JAMAK-C) ver sion.<br />

0,3<br />

0,5<br />

0,7<br />

0,9<br />

1,6<br />

4,5