CA BLE SIZES<br />
Data cab le, category 6, UTP (4 x 2 x 0,56 / AWG 23)<br />
UC 400 24 4P/UC 400 D 24 2 x 4P<br />
CON STRUC TION<br />
Conductor Copper wire, d=0,56 mm<br />
Insulation PE<br />
Type UC 400 24 4P UC 400 D 24 2 x 4P<br />
EAN code (SSTL code) 64 100+ 02 640 71 02 640 72<br />
Nomi nal di ame ters mm 5,2 5,2/10,4<br />
Mass kg/km 35 70<br />
De liv ery length m 500 500<br />
ELEC TRI CAL PROP ER TIES 20 °C<br />
Loop re sis tance, max Ω/km 176<br />
In su la tion re sis tance, min GΩ x km 2<br />
Nomi nal mu tual ca paci tance nF/km 48<br />
Maxi mum ca paci tance<br />
un bal ance, pair to ground pF/km ≤1500<br />
Nomi nal im ped ance Ω ƒ =1 - 100 MHz 100 ± 15<br />
Ve loc ity fac tor 0,78<br />
Maxi mum volt age V 75<br />
TRANSMISSION CHARACTERISTICS ACC. TO CATEGORY 6 (at 20 °C)<br />
Fre quency<br />
MHz<br />
1<br />
4<br />
10<br />
16<br />
20<br />
31,2<br />
62,5<br />
100<br />
125<br />
155,5<br />
175<br />
200<br />
250<br />
300<br />
400<br />
Attenuation<br />
(dB/100 m)<br />
NEXT<br />
(dB)<br />
PS-NEXT<br />
(dB)<br />
ACR<br />
(dB/100 m)<br />
PS-ACR<br />
(dB/100 m)<br />
ELFEXT<br />
(dB/100 m)<br />
DATA CA BLES<br />
PS-ELFEXT<br />
(dB/100 m)<br />
max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />
2,0<br />
3,8<br />
6,0<br />
7,6<br />
8,5<br />
10,7<br />
15,5<br />
19,9<br />
22,5<br />
25,4<br />
27,1<br />
29,2<br />
33,0<br />
1,9<br />
3,8<br />
6,0<br />
7,6<br />
8,5<br />
10,7<br />
15,1<br />
19,1<br />
21,3<br />
23,8<br />
25,3<br />
27,0<br />
33,0<br />
36,1<br />
41,7<br />
74<br />
65<br />
59<br />
56<br />
55<br />
52<br />
47<br />
44<br />
43<br />
42<br />
41<br />
40<br />
38<br />
78<br />
69<br />
63<br />
60<br />
59<br />
56<br />
51<br />
48<br />
47<br />
45<br />
44<br />
44<br />
42<br />
41<br />
39<br />
71<br />
62<br />
56<br />
53<br />
52<br />
49<br />
44<br />
41<br />
40<br />
39<br />
38<br />
37<br />
36<br />
75<br />
66<br />
60<br />
57<br />
56<br />
53<br />
48<br />
45<br />
44<br />
42<br />
41<br />
41<br />
39<br />
38<br />
36<br />
Unit Twisted pair<br />
Sheath Blue PVC<br />
72,0<br />
61,2<br />
53,0<br />
48,4<br />
46,5<br />
41,3<br />
31,5<br />
24,1<br />
20,5<br />
16,6<br />
13,9<br />
10,8<br />
5,0<br />
76,1<br />
65,2<br />
57,0<br />
52,3<br />
50,0<br />
45,0<br />
36,0<br />
28,9<br />
25,2<br />
21,3<br />
19,1<br />
16,5<br />
9,1<br />
4,8<br />
-2,7<br />
69,0<br />
58,2<br />
50,0<br />
45,4<br />
43,5<br />
38,3<br />
28,5<br />
21,1<br />
17,5<br />
13,6<br />
10,9<br />
7,8<br />
2,0<br />
73,1<br />
62,2<br />
54,0<br />
49,3<br />
47,0<br />
42,0<br />
33,0<br />
25,9<br />
22,2<br />
18,3<br />
16,1<br />
13,5<br />
6,1<br />
1,8<br />
-5,7<br />
67<br />
55<br />
47<br />
43<br />
41<br />
37<br />
31<br />
27<br />
25<br />
23<br />
22<br />
21<br />
20<br />
82<br />
70<br />
62<br />
58<br />
56<br />
52<br />
46<br />
42<br />
40<br />
38<br />
37<br />
36<br />
34<br />
32<br />
30<br />
65<br />
53<br />
45<br />
41<br />
39<br />
35<br />
29<br />
25<br />
23<br />
21<br />
20<br />
19<br />
17<br />
80<br />
68<br />
60<br />
56<br />
54<br />
50<br />
44<br />
40<br />
38<br />
36<br />
35<br />
34<br />
32<br />
30<br />
28<br />
Return<br />
loss<br />
(dB)<br />
23<br />
23<br />
23<br />
23<br />
23<br />
23<br />
23<br />
23<br />
21<br />
18,8<br />
18,4<br />
18,0<br />
17,3<br />
The right to al tera tions re served.<br />
75