14 PROCESS FABRICATIONS<br />

GMP TM<br />

The GMP fabrication can be utilized to virtually eliminate dead legs in<br />

the design of point-of-use outlets in a typical WFI distribution loop.The<br />

process fluid flows through the valve body. As demand warrants, the<br />

valve is opened, providing an uncontaminated sample untainted by<br />

bacterial growth or contaminants which may accumulate in outlets<br />

greater than 6D. The outlet can also be utilized as a steam condensate<br />

drain or as a divert port. The valve body has been modified to accept a<br />

third port of the same diameter or smaller, positioned adjacent to the<br />

weir at the bottom of the valve. Typically the GMP Valve is oriented in<br />

the vertical position. For horizontal process applications, the sterile<br />

access valve is recommended. The GMP configuration is available in<br />

sizes 1/4"–4" (DN 8–100) and can be supplied with buttweld or ferrule<br />

end connections.<br />

STERILE ACCESS PORTS<br />

The Sterile Access Port provides access to the interior of the valve<br />

body, at the lowest cross sectional point of the waterway, when the<br />

valve body is oriented at the optimum drain angle in a horizontal piping<br />

system.<br />

This port can be furnished as shown utilizing a valve or with various<br />

tube extension lengths and end connections. This Access Port can be<br />

used as a sampling, condensate drain or divert port. This fabrication is<br />

available in 316L stainless steel forgings, 1/4"-3" (DN 8-80) or investment<br />

castings, 2-1/2"-4" (DN 65-100).<br />

STANDARD ZERO STATIC WITH “U” BEND<br />

The Standard Zero Static fabrication is typically oriented as shown<br />

below and has excellent application properties in sampling, draining or<br />

diverting process fluids. The inherent dead leg, defined as the distance<br />

from the tubing/piping centerline to the valve weir, is minimized to<br />

comply with the FDA 6D guidelines in all possible size configurations.<br />

This fabrication is available in 316L stainless steel investment cast<br />

2-1/2"-4" (DN 65-100) or forged valve bodies, sizes 1/4"–2" (DN 8–50).<br />

ZERO STATIC “T” WITH “U” BEND<br />

The Zero Static “T” fabrication is a design modification of the<br />

Standard Zero Static, by significantly reducing the dead leg and area for<br />

product entrapment. The Zero Static “T” fabrication is optimally used in<br />

sampling, draining or diverting applications of critical process fluids.<br />

This fabrication is available in wrought 316L stainless steel 1/2"-2"<br />

valve (DN15-50) by 4" (DN100) header maximum.