MODULAR VALVE ASSEMBLIES<br />

AIR TO OPEN—AIR TO CLOSE<br />

SPRING TO OPEN—AIR TO CLOSE, FAIL OPEN<br />

1 Bio-Tek Valve series 2 Buttweld is 3.50"<br />

LIST OF PARTS 1/4"—2", DN 8—50<br />

ITEM DESCRIPTION MATERIAL QUANTITY<br />

1 Cover, Upper Actuator PAS, Cmpl with FDA Cfr #21 1<br />

2 Cover, Lower Actuator PAS, Cmpl with FDA Cfr #21 1<br />

3 Spindle, Valve S.S., ASTM A-582, Type 303 1<br />

4 Diaphragm, Actuator Buna N 1<br />

5 Plate, Actuator S.S. or Car Stl Nickel Pl. 2<br />

6 Spindle, Indicating S.S., ASTM A-582, Type 303 1<br />

7 Spring S.S., ASTM A-401 Nickel Pl. 1<br />

8 Spring S.S., ASTM A-401 Nickel Pl. 1<br />

9 “O” Ring* Viton, Cmpl with FDA Cfr #21 2<br />

10 Body, Weir 1/4"–2" S.S., Forge, or Inv. Cast 1<br />

11 Compressor S.S., C.I. Zinc or Bronze 1<br />

12 Diaphragm, Elastomer* EPDM, Cmpl with FDA Cfr #21 1<br />

13 Diaphragm, Plastic* TFE Cmpl with FDA Cfr #21 1<br />

14 Cushion, Backing* EPDM, Cmpl with FDA Cfr #21 1<br />

*Recommended spare parts<br />

AIR TO OPEN—SPRING TO CLOSE, FAIL CLOSED<br />

HEIGHT WITH ADAPTER SPOOL ADJUSTABLE OPENING STOP<br />

DIMENSIONAL DATA<br />

A B<br />

VALVE SIZE VALVE WITH LIMIT C D E H<br />

OPEN SWITCH, SP 2<br />

Inch DN Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm<br />

.25,.375,.51 8,10,151 4.27 108 9.40 239 2.84 72 2.50 63 2.532 64 Consult Factory<br />

0.50 15 4.89 124 9.93 252 3.34 85 3.00 76 3.50 89 6.39 162<br />

0.75 20 5.93 150 10.92 277 4.56 116 3.88 98 4.00 101 7.38 187<br />

1.00 25 6.55 166 11.35 288 4.56 116 3.88 98 4.50 114 7.94 202<br />

1.50 40 10.62 270 14.97 380 6.41 163 5.94 151 5.50 140 11.86 301<br />

2.00 50 11.39 289 15.41 391 6.41 163 5.94 151 6.25 159 12.56 319<br />