36 ADVANTAGE ® ACTUATOR A200<br />
REVERSE ACTION ACTUATORS—AIR-TO-OPEN, SPRING-TO-CLOSE, FAIL-CLOSE METAL BODIES<br />
PTFE* ELASTOMER DIAPHRAGM<br />
ACTUATOR SIZE SELECTION<br />
Maximum Line Pressure (psig, bar)<br />
Valve Size<br />
100% �P 0% �P<br />
Air Pressure<br />
Required to<br />
open, for full<br />
Actuator Bio-Tek** 0.50 0.75 1.00 1.50 2.00 3.00 4.00 Bio-Tek** 0.50 0.75 1.00 1.50 2.00 3.00 4.00<br />
stroke at 0<br />
PSI Line<br />
Model Bio-Tek** 15 20 25 32–40 50 80 100 Bio-Tek** 15 20 25 32–40 50 80 100 Pressure<br />
A203<br />
150<br />
10.34<br />
150<br />
10.34<br />
55<br />
3.79<br />
A204<br />
150<br />
10.34<br />
150<br />
10.34<br />
75<br />
5.17<br />
A205<br />
110<br />
7.58<br />
90<br />
6.21<br />
50<br />
3.45<br />
A206<br />
150<br />
10.34<br />
150<br />
10.34<br />
90<br />
6.21<br />
A208<br />
100<br />
6.89<br />
60<br />
4.14<br />
45<br />
3.10<br />
A208<br />
150<br />
10.34<br />
80<br />
5.52<br />
60<br />
4.14<br />
A209<br />
150 150<br />
10.34 10.34<br />
120<br />
8.27<br />
130<br />
8.96<br />
90<br />
6.21<br />
A216<br />
100<br />
6.89<br />
65<br />
4.48<br />
50<br />
3.45<br />
A216<br />
70<br />
4.83<br />
30<br />
2.07<br />
60<br />
4.14<br />
A217<br />
150<br />
10.34<br />
150<br />
10.34<br />
130<br />
8.96<br />
75<br />
5.17<br />
90<br />
6.21<br />
A233<br />
95 70<br />
6.55 4.83<br />
60<br />
4.14<br />
35<br />
2.41<br />
62<br />
4.28<br />
A234<br />
150 110<br />
10.34 7.59<br />
92<br />
6.34<br />
50<br />
3.45<br />
85<br />
5.86<br />
A247<br />
150<br />
10.34<br />
92<br />
6.34<br />
57<br />
3.93<br />
A247<br />
119<br />
8.20<br />
59<br />
4.07<br />
60<br />
4.14<br />
A248<br />
150<br />
10.34<br />
150<br />
10.34<br />
76<br />
5.24<br />
A248<br />
150<br />
10.34<br />
93<br />
6.41<br />
82<br />
5.65<br />
A203<br />
70<br />
10.34<br />
55<br />
3.79<br />
55<br />
3.79<br />
A204<br />
150<br />
10.34<br />
125<br />
8.62<br />
75<br />
5.17<br />
A205<br />
70<br />
4.83<br />
50<br />
3.45<br />
65<br />
4.48<br />
A206<br />
150<br />
10.34<br />
150<br />
10.34<br />
90<br />
6.21<br />
A208<br />
140<br />
9.65<br />
70<br />
4.83<br />
60<br />
4.14<br />
A208<br />
100<br />
6.89<br />
35<br />
2.41<br />
70<br />
4.83<br />
A209<br />
150 150<br />
10.34 10.34<br />
80<br />
5.52<br />
80<br />
5.52<br />
90<br />
6.21<br />
A216<br />
125<br />
8.62<br />
70<br />
4.83<br />
50<br />
3.45<br />
A216<br />
60<br />
4.14<br />
45<br />
3.10<br />
60<br />
4.14<br />
A217<br />
150<br />
10.34<br />
150<br />
10.34<br />
125<br />
8.82<br />
70<br />
4.83<br />
90<br />
6.21<br />
A233<br />
50 30<br />
3.45 2.07<br />
20<br />
1.38<br />
15<br />
1.03<br />
62<br />
4.28<br />
A234<br />
105 60<br />
7.24 4.14<br />
45<br />
3.10<br />
30<br />
2.07<br />
85<br />
5.86<br />
A247<br />
133 70<br />
9.17 4.83<br />
68<br />
4.69<br />
61<br />
4.21<br />
A247<br />
41<br />
2,83<br />
62<br />
4,27<br />
A248<br />
150 126<br />
10.34 8.69<br />
114<br />
7.86<br />
82<br />
5.65<br />
A248<br />
70<br />
4.83<br />
90<br />
6.21<br />
*The exposure of the diaphragm to steam may de-rate the shut off line pressure as much as 30%. **Bio-Tek includes sizes 0.25, 0.37, 0.50" (DN 8, 10, 15).