14<br />

inner Ø= 40mm<br />

min. inner Ø= 37mm<br />

10°<br />

l<br />

inner Ø= >40mm<br />

Water-quality information:<br />

– Use only fresh drinking water to supply the appliance. It is not permissible<br />

to supply the appliance with water from open water courses,<br />

because of the high germ count (microorganisms).<br />

– We recommend the use of a demineralization system, (e.g. a reverseosmosis<br />

system) when the water is very hard (mineral-rich).<br />

Caution! Fully demineralized water (VE water) from a reverseosmosis<br />

system is aggressive. In this case all lines <strong>and</strong> connectors of<br />

the water installation (supply <strong>and</strong> drain) must be made of stainless steel<br />

(minimum requirements according to DIN 1.4301) or plastic.<br />

Note: Base exchangers (water softeners) are not suitable for watertreatment<br />

purposes because they do not reduce the quantity of minerals<br />

dissolved in the water. Phosphate cartridges are also unsuitable because<br />

they increase the minerals dissolved in the water.<br />

– Do not add disinfectants to the water. These are discharged into the<br />

ambient air during the atomization process <strong>and</strong> may cause mucousmembrane<br />

irritation or allergies.<br />

Please consult your <strong>Defensor</strong> dealer if you have questions concerning<br />

water treatment.<br />

Water drain line<br />

Basic units SU11 <strong>and</strong> DU11 with automatic flushing<br />

Via a siphon trap, connect the drain of the basic unit (inner Ø= 40mm)<br />

to a drain line of the building (inner Ø >40mm). Use rigid plastic pipe<br />

(min. inner Ø= 37mm) for the connection <strong>and</strong> route the pipe with a<br />

downward pitch of at least 10°. To ensure that the entire reservoir<br />

content can be discharged when the appliance is emptied, the connecting<br />

pipe should not be shorter than:<br />

– for the SU11 base unit: about 1m – for DU11 base unit: about 2m Use a hose clip on the drain connection to fasten the installed line.<br />

Notes:<br />

– It is advisable to use steel piping (min. requirements according to<br />

DIN 1.4301 if VE-water is used) for the drain line in exposed locations.<br />

– For safety reasons, do not use flexible tubing for the drain line.<br />

Base units SU21 <strong>and</strong> DU21 with automatic level security device<br />

The drain connections on base units SU21 <strong>and</strong> DU21 are closed with a<br />

drain pipe with a threaded cap. The drain cap is not installed when the<br />

appliance is delivered. To install the drain pipe, proceed as follows:<br />

• Insert the drain pipe into the drain connection until it comes to a stop,<br />

then secure it with the hose clip.