Malfunction Cause Remedy<br />

The atomizer keeps running<br />

<strong>and</strong> cannot be switched off by<br />

reducing the reference humidity<br />

value.<br />

The humidistat does not switch.<br />

The atomizer does not run.<br />

The humidistat activates the atomizer,<br />

but the atomizer does<br />

not start.<br />

The set reference humidity value<br />

is not reached. The atomizer runs<br />

continuously.<br />

The atomizer runs noisily (motor<br />

noise audible).<br />

Air humidity very low (95 % rh).<br />

Humidistat defective.<br />

Humidistat incorrectly set.<br />

Atomizer fuse F1 in base-unit terminal<br />

box is defective.<br />

The mains connection to the particular<br />

humidifier is interrupted.<br />

The electric cable of the atomizer<br />

unit is not connected.<br />

The thermostatic switch of the electric<br />

motor has tripped (motor is overheated).<br />

Air filters heavily contaminated.<br />

Room too large.<br />

Suction tube of atomizer unit<br />

blocked.<br />

Suction tube not installed.<br />

Disks not correctly installed.<br />

Suction tube has become undone.<br />

None.<br />

Check humidistat. Replace if necessary.<br />

None.<br />

Check humidistat. Replace if necessary.<br />

Set humidistat to the correct reference<br />

humidity value.<br />

Replace atomizer fuse F1.<br />

Check the wiring.<br />

Plug the atomizer-unit cable into<br />

the base unit<br />

Check the atomizing head (The<br />

motor shaft must rotate freely).<br />

Clean if necessary. Contact <strong>Defensor</strong><br />

dealer if necessary<br />

Clean air filters.<br />

Contact <strong>Defensor</strong> dealer.<br />

Check suction tube. Clean if necessary.<br />

Install suction tube.<br />

Check disks. Mount them correctly.<br />

Tighten suction tube.<br />