6.4 Humidifier reassembly<br />

24<br />

Cleaning the air system<br />

Filter units<br />

– If the filter units are only lightly contaminated: clean the outside<br />

surface of the filter units with a vacuum cleaner.<br />

– If the filter units are heavily contaminated: replace them.<br />

Important notes:<br />

– Apply the vacuum cleaner only to the outside surface of the filter units<br />

so that the contaminatory matter does not penetrate deeper into the<br />

filter fabric <strong>and</strong> reduce the efficiency of the filter.<br />

– The filter units must not be used for more than 1 year. Under severe<br />

operating conditions, the maximum service time must be reduced<br />

accordingly.<br />

– Install only absolutely dry filters. Damp filters promote the growth of<br />

microorganisms.<br />

Discharge housing / aerosol discharge hood <strong>and</strong> directing hood<br />

Wash all components with a lukewarm soap solution <strong>and</strong> then rinse<br />

thoroughly with water.<br />

Note: observe the instructions regarding cleaning agents in the “Cleaning<br />

the water system” section.<br />

Before starting with the reassembly, check all components for operational<br />

integrity <strong>and</strong> any defects. Pay special attention to the float switches <strong>and</strong> the<br />

drain valve (SU11 <strong>and</strong> DU11 only). Replace defective components.<br />

Reservoir installation<br />

• Insert the reservoir on the drain connection side into the retainer of the<br />

base unit, swing upwards <strong>and</strong> secure with the retaining latches.<br />

• Push the drain tubing onto the connection on the reservoir.<br />

• Caution! In the case of the SU21/DU21 base units, secure the drain<br />

tubing with a hose clip <strong>and</strong> close the drain tube with the threaded<br />

cap.<br />

Filter unit installation<br />

• Insert filter unit(s) (FU1 or FU2) from underneath into the retainers of the<br />

base unit. Swing up <strong>and</strong> secure with the retaining latches.<br />

Note: The filter units are square <strong>and</strong> their orientation is immaterial.