22<br />
12<br />
11a<br />
Atomizer unit removal<br />
• Unplug the electric cable(s) between the atomizer unit(s) <strong>and</strong> the base<br />
unit.<br />
• AU90: Lift off the aerosol discharge hood <strong>and</strong> then the directing hood<br />
(11a). Remove the ring filter unit (12, if installed).<br />
AU35: Undo the two catches <strong>and</strong> lift off the discharge housing together<br />
with the flat filter (11b).<br />
• Carefully lift the atomizer unit (10) on the carrier frame (1a/1b) up <strong>and</strong><br />
out of the base unit.<br />
• Place the atomizer unit (10) together with the fan wheel downwards onto<br />
the carrier frame. Make sure that the unit does not st<strong>and</strong> on the fan<br />
wheel (use wooden blocks).<br />
• Hold the disks (9) (guide disk (2), distributor cone (3), 3 spinning disks<br />
(4) <strong>and</strong> impeller (5)) firmly <strong>and</strong> undo the suction tube (6) in an anticlockwise<br />
direction.<br />
• Remove the disks (9) from the drive shaft. Press the impeller <strong>and</strong> spinning<br />
disks away from the distributor cone by h<strong>and</strong>. Then, remove the<br />
distributor cone from the guide disk.<br />
• Pull the catch springs outwards <strong>and</strong> carefully withdraw the atomizer<br />
grid (7) from the centring device.<br />
• Remove the insert (8) from the base unit.<br />
1a<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
1b<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11b