Figure 2 Model rectangular building<br />

Figure 3 Model bubble<br />

Both models were simulated in Radiance and this resulted in<br />

the conclusion that regarding the overall daylighting quality<br />

none of the buildings is significantly better than the other one.<br />

The daylight distribution is better in the bubble, due to the<br />

possibility of the different placement of the openings.<br />

In a simulation with a sunny sky with sun glare occurs in both<br />

buildings in the compared north-facing viewpoints, caused by<br />

reflections on the wall, on the floor or on reveals. In the southfacing<br />

viewpoints glare is also caused by the sky.<br />

From the simulations with the overcast sky is concluded that<br />

glare will occur at a free field luminance of 14024 lux in the<br />

bubble and of 14937 lux in the rectangular building. Regarding<br />

the luminances, these are variable depending on the sky used in<br />

the simulation and the position of the window. None of the buildings<br />

is distinctively better in this criterion.<br />

Regarding the luminance ratios it is depending on the type of<br />

sky which building is better. In an overcast sky situation the<br />

luminance ratios are lower in the bubble; in a situation with a<br />

sunny sky the rectangular building gives lower luminance ratios.<br />

But in both situations with the north-facing viewpoints the<br />

requirement is exceeded, due to low luminances on the wall.<br />

The vertical illuminance turned out to be too complex to make a<br />

fair comparison.<br />

In the end some recommendations are made regarding<br />

solutions for the problems concerning daylighting quality and<br />

regarding interesting additional research. Solutions for the glare<br />

in the north-facing positions are changing the angle under<br />

which the window is placed and increasing the absorption factor<br />

of the reveals. A solution for the problems concerning the<br />

luminance ratio is to increase the luminances on the wall by<br />

artificial lighting. Furthermore the suggestion is done to create a<br />

tool for designers to make them aware of the influence of the<br />

sun in order to make the right decision regarding the<br />

positioning of the openings during the design process.<br />

In order to find a way to suppress brightness in an architectural<br />

acceptable way in buildings with curved glazing an overview is<br />

made of existing glare protection and sun-shading systems.<br />

These systems are divided into four groups: external systems,<br />

glass systems, systems in the cavity of the glazing and internal<br />

systems. A selection of these systems was made based on their<br />

applicability to double curved glazing. The selected systems are<br />

judged based on seven criteria: the influence on the indoor<br />

climate, the adjustability of the system, maintenance, the<br />

manufacturing procedure, the light transmission, the costs and<br />

whether the system is active or passive. This resulted in the so<br />

called switchable systems being the most suitable systems for<br />

double curved glazing. Switchable systems are photochromic,<br />

thermochromic, thermotropic and electrochromic glass and<br />

gas-chromatic systems. Of these systems electrochromic glass is<br />

chosen to evaluate its influence by implementing it in the<br />

simulation models.<br />

Electrochromic glass has, even in a clear state, a significantly<br />

lower transmittance than normal clear glass. This has a transmittance<br />

of 0.8, while the transmittance of electrochromic glass<br />

is 0.5 in clear state and 0.15 in shaded state. This resulted in a<br />

large decrease of the amount of light entering the building.<br />

Where in the original situation the building was qualified in an<br />

overcast sky situation as being well lit by daylight, the<br />

qualification in case of clear electrochromic glass degraded to<br />

moderately lit and in case of shaded electrochromic glass to<br />

dark. Nevertheless, the exceeding of the luminance ratios still<br />

occurred in the overcast sky situation, because the luminance on<br />

the wall also decreased due to the smaller amount of light entering<br />

the building.<br />

The recommendations regarding glare protection and sun-shading<br />

in buildings with curved façades are to develop shading<br />

scenarios for different times and days. In these scenarios only<br />

the windows for which shading is necessary at that time are<br />

shaded. Concerning further research it is recommended to look<br />

at the implementation of double curved glass in the<br />

manufacturing procedures of glare protection and sun-shading<br />

systems.<br />