4. CÁLCULO DO TEMPO DE MISTURA DA ETAR (t):<br />

t = 14,73/0,0167 = 882 s = 14,7 min<br />

5. CÁLCULO DA POTÊNCIA DO AGITADOR (t):<br />

• Volume do copo Jar Test (V) = 0,5 l = 0,0005 m 3<br />

P = 1,139 x 10 -3 x 0,0005 x 33 2 = 0,00062 w<br />

6. CÁLCULO DA VELOCIDADE DAS PÁS (vp):<br />

• Velocida<strong>de</strong> das pás (vp), m/s;<br />

• Coeficiente <strong>de</strong> atrito,para lâminas lisas, (CD) = 1,8;<br />

• Densida<strong>de</strong> da água ( ρ ) = 1000 Kg/m 3 ;<br />

• Área das Pás em m 2 (AP) = 15 cm 2 = 15 x 10 -4 m 2 .<br />

0,<br />

00062 × 2<br />

vp = 0,077 m/s<br />

−4<br />

1,<br />

8 × 1000 × 15 × 10<br />

=> = 3<br />

7. CÁLCULO DA VELOCIDADE REAL(vr):<br />

• Velocida<strong>de</strong> real (vr), m/s.<br />

vr = 0,103 m/s<br />

V<br />

t =<br />

Q<br />

P = μ × V × G<br />

vp =<br />

3<br />

C<br />

D<br />

vp<br />

vr =<br />

0,<br />

75<br />

2<br />

P × 2<br />

× ρ × A<br />

P