Packaged Gas/Electric Rooftop Units - Trane
Packaged Gas/Electric Rooftop Units - Trane
Packaged Gas/Electric Rooftop Units - Trane
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
76<br />
Performance<br />
Data<br />
Table PD-92— Hot <strong>Gas</strong> Reheat Temperature Rise 3<br />
SCFM Leaving Evaporator Dry Bulb [F]<br />
Tons SCFM 35 40 45 50 55 60 65<br />
960 17.6 17.3 17.0 16.6 16.2 15.8 15.5<br />
1080 16.7 16.4 16.1 15.7 15.4 15.0 14.6<br />
3 1200 15.8 15.5 15.2 14.9 14.5 14.1 13.8<br />
1320 14.9 14.6 14.3 14.0 13.6 13.3 12.9<br />
1440 14.0 13.8 13.5 13.1 12.8 12.4 12.0<br />
Tons SCFM 35 40 45 50 55 60 65<br />
1280 19.0 18.7 18.4 18.1 17.9 17.5 17.2<br />
1440 17.9 17.7 17.4 17.1 16.9 16.5 16.2<br />
4 1600 16.9 16.6 16.4 16.1 15.8 15.5 15.2<br />
1760 15.9 15.6 15.4 15.1 14.8 14.5 14.2<br />
1920 14.8 14.6 14.4 14.1 13.8 13.5 13.2<br />
Tons SCFM 35 40 45 50 55 60 65<br />
1600 20.3 20.1 19.9 19.7 19.5 19.3 19.0<br />
1800 19.1 18.9 18.7 18.5 18.4 18.1 17.8<br />
5 2000 17.9 17.8 17.6 17.4 17.2 16.9 16.6<br />
2200 16.8 16.6 16.4 16.2 16.0 15.7 15.4<br />
2400 15.6 15.4 15.2 15.1 14.9 14.6 14.3<br />
Tons SCFM 35 40 45 50 55 60 65<br />
2400 16.7 17.3 18.0 18.7 19.3 20.1 20.9<br />
2700 14.9 15.5 16.1 16.7 17.3 18.0 18.7<br />
7½ 3000 13.1 13.7 14.2 14.7 15.2 15.9 16.5<br />
3300 11.4 11.8 12.3 12.7 13.1 13.7 14.3<br />
3600 9.6 10.0 10.3 10.7 11.1 11.6 12.2<br />
Tons SCFM 35 40 45 50 55 60 65<br />
2720 16.6 17.4 18.2 18.9 19.7 20.3 21.0<br />
3060 14.7 15.3 15.9 16.6 17.2 17.7 18.1<br />
8½ 3400 12.7 13.2 13.7 14.2 14.7 15.0 15.3<br />
3740 10.7 11.1 11.4 11.8 12.2 12.3 12.5<br />
4080 8.7 9.0 9.2 9.4 9.6 9.7 9.7<br />
Tons SCFM 35 40 45 50 55 60 65<br />
3200 18.7 19.5 20.3 21.2 22.0 22.7 23.4<br />
3600 16.2 17.2 18.1 19.1 20.1 20.8 21.6<br />
10 4000 13.8 14.9 15.9 17.0 18.1 19.0 19.8<br />
4400 11.3 12.5 13.7 14.9 16.1 17.1 18.1<br />
4800 8.9 10.2 11.5 12.9 14.2 15.3 16.3<br />
Notes:<br />
1. Temperature rise does not account for indoor fan heat.<br />
2. 70 deg OD Ambient Temperature.<br />
3. For units with the Dehumidification (Hot <strong>Gas</strong> Reheat) option.<br />
RT-PRC006-EN