02.06.2013 Views

SIMATIC PCS 7 Process Control System - Siemens

SIMATIC PCS 7 Process Control System - Siemens

SIMATIC PCS 7 Process Control System - Siemens

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

■ Selection and Ordering Data Order No.<br />

SIGUARD Terminal Modules<br />

PM-PF30 S47 B1 Terminal<br />

Module<br />

For PM-D F1/2 power modules<br />

with U1/U2 incoming supply and<br />

sensor connection<br />

PM-PF30 S47 B0 Terminal<br />

Module<br />

For PM-D F1/2 power modules<br />

with sensor connection<br />

PM-PF30 S47 C1 Terminal<br />

Module<br />

For PM-D F3/4 power modules<br />

with U1/U2 incoming supply and<br />

IN+/IN- control input<br />

PM-PF30 S47 C0 Terminal<br />

Module<br />

For PM-D F3/4 power modules<br />

with U2 incoming supply<br />

PM-PF30 S47 D0 Terminal<br />

Module<br />

For PM-D F5 power modules<br />

PM-X15 S27 01 Terminal Module<br />

For SIGUARD connection module<br />

SIGUARD Power Modules<br />

PM-D F1 SIGUARD Power<br />

Module<br />

EMERGENCY STOP; monitored<br />

start; 2-channel<br />

PM-D F2 SIGUARD Power<br />

Module<br />

Protective door; autostart;<br />

2-channel<br />

PM-D F3 SIGUARD Power<br />

Module<br />

Expansion to F1/2 for an additional<br />

voltage group;<br />

time-delayed<br />

PM-D F4 SIGUARD Power<br />

Module<br />

Expansion to F1/2 for an additional<br />

voltage group<br />

PM-D F5 SIGUARD Power<br />

Module<br />

Expansion to PM-D F1 up to<br />

PM-D F4, contact multiplier<br />

3RK1 903-1AA00 A)<br />

3RK1 903-1AA10 A)<br />

3RK1 903-1AC00 A)<br />

3RK1 903-1AC10<br />

3RK1 903-1AD10<br />

3RK1 903-1AB00 A)<br />

3RK1 903-1BA00<br />

3RK1 903-1BB00<br />

3RK1 903-1BD00<br />

3RK1 903-1BC00<br />

3RK1 903-1BE00<br />

© <strong>Siemens</strong> AG 2007<br />

<strong>Process</strong> I/O<br />

ET 200S distributed I/O<br />

SIGUARD safety technology<br />

■ Selection and Ordering Data<br />

Accessories<br />

Order No.<br />

PM-X SIGUARD<br />

Connection module for incomingfeeder<br />

contactor; external safety<br />

circuits<br />

3RK1 903-1CB00 A)<br />

Failsafe kit 1<br />

Failsafe kit for DS1-x standard<br />

motor starter (not necessary for<br />

High Feature motor starter)<br />

3RK1 903-1CA00 A)<br />

Failsafe kit 2<br />

Failsafe kit for RS1-x standard<br />

motor starter (not necessary for<br />

High Feature motor starter)<br />

3RK1 903-1CA01 A)<br />

A) Subject to export regulations: AL: N, ECCN: EAR99<br />

<strong>Siemens</strong> ST <strong>PCS</strong> 7 · November 2007<br />

11/55<br />

11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!