Quartermaster Supply Operations - US Army Combined Arms Center ...
Quartermaster Supply Operations - US Army Combined Arms Center ...
Quartermaster Supply Operations - US Army Combined Arms Center ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
SECTION 1<br />
HEFRIGEWMON UNITS<br />
L33. &artcrmastor Refrigeration Company (Bixod) T/O & E<br />
10-217,<br />
a. Organization and Mission, The company with an<br />
aggregate of 142 enlisted men and five officers operated and<br />
maintained Corps of Jhgineer refrigeration equipment and<br />
civilian refrigerated storage p1ants.l It was organized into<br />
three platoons: (1 headquarters platoon, a butchery pintoon<br />
and a cold storage platoon with attached personnel Prom the<br />
Veterinary Corps for mat inspection purposes.2 Under many<br />
cordi ions it w;i8 not necessary to activate the butchery pln-<br />
toon. P<br />
b. Use. The capacity of the company was determined<br />
by the particux situation, since the aveilable storage<br />
ftlcilities governed the amount that it could handle. When<br />
Engineer collapsible refrigeratton box s were used the comljany<br />
served as mmy as 120,000 troops.! Under coilditions<br />
dherein the company personnel acted in a supervieory capacity<br />
and employed civilians end pri onera of war, approximtely<br />
650,000 troops were oupgorted.3 This company wa~inot used<br />
in the Combat Zone, but it did meet all expectations in<br />
connection with the use of collaysible refrigeration boxes.3<br />
c. lidointenanoe.' The <strong>Quartermaster</strong> responsi bilitg<br />
in maintning refrigeration facilities was limited to the<br />
repair of the refrigeration units coolim the mobile vans.<br />
A11 oi' the reaainlng maintenance responsibilities were<br />
divided among the other servicea. The responsibilities of<br />
the Corps of Engiiaers, for example, inoluded:<br />
(1) Repnir to existing cold storage nnd ice<br />
facilities.<br />
(2) Operation and mnfntenance of all statio<br />
refrigeration plants.<br />
In the European Theater of <strong>Operations</strong> Engineer personiel<br />
were preoccupied with other activities which were basic in<br />
advancing the war effort, hence their responsibilities were<br />
aesumed by the using unit or other u,uartermc?ster agencies.<br />
134. Quarteraaster Refrigeration Company (Mobile) T/O<br />
& E 10-24.7,<br />
n, Orgnhixntion and Mission. The Quurtekmster<br />
1-frigeration Company (Uobile) was organized into three plntoons<br />
of three sections eaoh. Each section and platoon was<br />
capable of operating independently.5 The mission of the<br />
company was to transport fresh meats and other perishables<br />
from the advance depot or other point where fixed refrigeration<br />
was provided to the division or army supply points.<br />
When the turn around time between the loading point and the<br />
- 89 -<br />
R-E-S-T-R-I-C -T-E-D