■ Overview<br />
■ Technical specifications<br />
Data transmission rate<br />
Interfaces<br />
9.6 kbit/s to 12 Mbit/s<br />
Connection to PROFIBUS 9-pin Sub-D socket<br />
Connection to PG/PC PCI (32-bit)<br />
Power supply +5 V DC ± 5 %<br />
Current consumption 0.5 A<br />
Power loss<br />
Perm. ambient conditions<br />
2.0 W<br />
Operating temperature +5 °C to +40 °C<br />
Transport/storage temperature -20 °C to +60 °C<br />
Relative humidity Max. 95% at +25 °C<br />
Programming devices<br />
Accessories<br />
Siemens ST 70 · 2005<br />
CP 5611<br />
For connecting the programming device or PC to PROFIBUS<br />
and the MPI of <strong>SIMATIC</strong> S7<br />
Communication services:<br />
- PROFIBUS DP master Class 1 including acyclic DP<br />
expansions with SOFTNET-DP<br />
- PROFIBUS DP master Class 2 including acyclic DP<br />
expansions with SOFTNET-DP<br />
- PROFIBUS DP slave with SOFTNET-DP slave<br />
- PG/OP communication<br />
- S7 communication with SOFTNET-S7<br />
- S5-compatible communication (SEND/RECEIVE based<br />
on the FDL interface) with SOFTNET-DP or SOFTNET-S7<br />
Short PCI card; for programming devices and PCs with<br />
a PCI slot (32 bits)<br />
Can be used with:<br />
- STEP 7, STEP 7-Micro/Win, ProTool, ProTool/Pro,<br />
<strong>SIMATIC</strong> PDM (for PG/OP communication)<br />
- COM PROFIBUS<br />
- SOFTNET-S7 (for S7 communication)<br />
- SOFTNET-DP, SOFTNET-DP slave (for DP)<br />
The appropriate OPC server and configuration tools are<br />
included in the scope of supply of the respective communication<br />
software<br />
Construction<br />
Module format PCI card<br />
Dimensions (W x H x D) in mm 102 x 130<br />
Weight Approx. 100 g<br />
Space requirements 1 x PCI slot<br />
DP master DP-V0, DP-V1 with SOFTNET-DP<br />
DP slave DP-V0, DP-V1 with SOFTNET-DP<br />
slave<br />
8/21<br />
8