■ Technical specifications (continued)<br />

Actuator connection<br />

- for voltage output 2-wire<br />

connection<br />

- for voltage output 4-wire<br />

connection<br />

- for current output 2-wire<br />

connection<br />

6ES7 636-2EC00-0AE3<br />

Yes; without cable resistance<br />

compensation<br />

No<br />

Yes<br />

Burden resistance<br />

(in the nominal output range)<br />

- at voltage outputs, min. 1 kOhm<br />

- at voltage outputs, capacitive 0.1 µF<br />

load, max.<br />

- at current outputs, max. 300 Ω<br />

- at current outputs, inductive 0.1 mH<br />

load, max.<br />

Destruction limit against voltages<br />

and currents applied from outside<br />

- Voltages at the outputs<br />

16 V; permanent<br />

against MANA<br />

- Current (DC), max. 50 mA; permanent<br />

Analog value formation<br />

Measuring principle Measuring principle Encoding of<br />

instantaneous value (successive<br />

approximation)<br />

Integration and conversion<br />

time/triggering per channel<br />

- with over-range (bits incl. sign), 12 Bit<br />

max.<br />

- Integration time parameterizable Yes; 2.5 / 16.6 / 20 ms<br />

- Permissible input frequency, 400 Hz<br />

max.<br />

- Conversion time (per channel) 1 ms<br />

- Response time of the input filter 0.38 ms<br />

- Basic execution time of the 1 ms<br />

module (all channels enabled)<br />

Settling time<br />

- for resistive load 0.6 ms<br />

- for capacitive load 1 ms<br />

- for inductive load 0.5 ms<br />

Sensor<br />

Connectable encoders<br />

- 2-wire BEROS Yes<br />

- permissible closed-circuit 1.5 mA<br />

current (2-wire BEROS), max.<br />

Error/accuracies<br />

Operational limit in the entire<br />

temperature range<br />

- Relative to the output range,<br />

voltage<br />

- Relative to the output range,<br />

current<br />

- relative to the input range,<br />

voltage<br />

- relative to the input range,<br />

current<br />

- relative to the input range,<br />

resistance<br />

+/- 1 %<br />

+/- 1 %<br />

+/- 1 %<br />

+/- 1 %<br />

+/- 5 %<br />

Basic error limit<br />

(operational limit at 25 °C)<br />

- relative to the output range,<br />

voltage<br />

- relative to the output range,<br />

current<br />

- relative to the input range,<br />

voltage<br />

- relative to the input range,<br />

current<br />

- relative to the input range,<br />

resistance<br />

- relative to the input range,<br />

resistance thermometer<br />

Interference voltage suppression<br />

for f = n x (fl +/- 1 %)<br />

- Series-mode interference<br />

(peak value of interference<br />

< rated value input range)<br />

- Common-mode interference,<br />

min.<br />

Integral functions<br />

<strong>SIMATIC</strong> C7<br />

Control systems<br />

6ES7 636-2EC00-0AE3<br />

+/- 0,7 %<br />

+/- 0,7 %<br />

+/- 0,7 %<br />

+/- 0,7 %<br />

+/- 3 %<br />

+/- 3 %<br />

30 dB<br />

40 dB<br />

Number of counters 4; in total 4 channels<br />

Count frequency (counters) max. 60 kHz<br />

Frequency sensor Yes<br />

Frequency measurement Yes<br />

Number of frequency sensors 4; in total 4 channels<br />

Controlled positioning Yes<br />

Integrated function blocks<br />

(control)<br />

Yes<br />

PID controller Yes<br />

Pulse outputs Yes<br />

Number of pulse outputs 4; in total 4 channels<br />

Cut-off frequency (pulse)<br />

Status information/ interrupts/<br />

diagnostics<br />

2.5 kHz<br />

Siemens ST 70 · 2005<br />

C7-636<br />

Interrupts<br />

- Interrupts Yes;<br />

- No interrupts when used as<br />

standard I/O.<br />

- When using the technological<br />

functions see the S7-300 Automation<br />

System manual, CPU31xC<br />

Technological Functions.<br />

Diagnostics<br />

- Diagnostic functions No;<br />

- No diagnostics when using as<br />

standard I/O.<br />

- When using the technological<br />

functions<br />

see the S7-300 Automation System<br />

manual, CPU31xC Technological<br />

Functions.<br />

6/27<br />