9<br />

PC-based Automation<br />

PC-based Control<br />

<strong>SIMATIC</strong> WinAC <strong>Software</strong> PLC<br />

■ Overview<br />

Optimized for applications th at demand high flexibility and<br />

integration capability.<br />

<strong>SIMATIC</strong> WinAC software PLCs comprise the following products<br />

- WinAC Basis and<br />

-WinAC RTX.<br />

WinAC Basis:<br />

- The low-cost solution for PC-based control tasks.<br />

- For data-intensive processes in connection with extensive<br />

PC tasks.<br />

■ Technical specifications<br />

6ES7 671-<br />

0CC03-0YA0<br />

Memory/backup<br />

Memory<br />

Load memory<br />

- integral RAM, max. PC working<br />

memory<br />

usable<br />

CPU/blocks<br />

DB<br />

- Number, max. Limited only by<br />

the the amount<br />

of available<br />

PC working<br />

memory<br />

9/4<br />

Siemens ST 70 · 2005<br />

6ES7 671-<br />

0RC04-0YA0<br />

PC main memory<br />

can be<br />

used (non<br />

paged memory)<br />

Limited only by<br />

the the amount<br />

of available<br />

PC working<br />

memory<br />

- Size, max. 64 KByte 64 KByte<br />

FB<br />

- Number, max. Limited only by<br />

the the amount<br />

of available<br />

PC working<br />

memory<br />

Limited only by<br />

the the amount<br />

of available<br />

PC working<br />

memory<br />

- Size, max. 64 KByte 64 KByte<br />

FC<br />

- Number, max. Limited only by<br />

the the amount<br />

of available<br />

PC working<br />

memory<br />

Limited only by<br />

the the amount<br />

of available<br />

PC working<br />

memory<br />

- Size, max.<br />

OB<br />

64 KByte 64 KByte<br />

- Size, max. 64 KByte 64 KByte<br />

WinAC RTX:<br />

- The software solution for tasks which demand hard<br />

deterministics.<br />

- With real-time extension to provide deterministic behavior for<br />

the control unit.<br />

<strong>SIMATIC</strong> WinAC software PLCs each comprise the following<br />

components:<br />

Windows logic controller<br />

OPC server and ActiveX components<br />

Driver for PROFIBUS CPs<br />

VenturCom RTX real-time kernel (WinAC RTX only)<br />

Optional:<br />

CP for connecting to PROFIBUS DP:<br />

- CP 5611 or the integral PROFIBUS interface on the<br />

<strong>SIMATIC</strong> PC (WinAC Basis only)<br />

- CP 5613 A2.<br />

<strong>SIMATIC</strong> WinAC PN option<br />

- Permits communication between WinAC Basis and further<br />

automation systems based on PROFINET CBA via <strong>Industrial</strong><br />

Ethernet.<br />

WinAC Open Development Kit (ODK):<br />

- For using C/C++ code in WinAC Basis or WinAC RTX<br />

- For integrating external software (technology programs) or<br />

PC components (e.g. scanners, PC cards for measured data<br />

acquisition)<br />

6ES7 671-<br />

0CC03-0YA0<br />

6ES7 671-<br />

0RC04-0YA0<br />

CPU/blocks (continued)<br />

Nesting depth<br />

- per priority class 24 24<br />

- additional levels within an<br />

error OB<br />

CPU/processing times<br />

24 24<br />

for bit instruction, min. 0.013 µs; typ. 0.013 µs; typ.<br />

for integer math, min. 0.025 µs; typ. 0.025 µs; typ.<br />

for floating-point math, min. 0.025 µs; typ. 0.025 µs; typ.<br />

Reference platform Pentium IV, Pentium IV,<br />

Timers/counters and their<br />

retentive characteristics<br />

S7 counter<br />

2.4 GHz 2.4 GHz<br />

- Number<br />

Retentivity<br />

512 512<br />

- adjustable Yes Yes<br />

- lower limit 0 0<br />

- upper limit 511 511<br />

- preset<br />

Counting range<br />

8 8<br />

- adjustable Yes Yes<br />

- lower limit 0 0<br />

- upper limit 999 999