9<br />
PC-based Automation<br />
PC-based Control<br />
<strong>SIMATIC</strong> WinAC <strong>Software</strong> PLC<br />
■ Overview<br />
Optimized for applications th at demand high flexibility and<br />
integration capability.<br />
<strong>SIMATIC</strong> WinAC software PLCs comprise the following products<br />
- WinAC Basis and<br />
-WinAC RTX.<br />
WinAC Basis:<br />
- The low-cost solution for PC-based control tasks.<br />
- For data-intensive processes in connection with extensive<br />
PC tasks.<br />
■ Technical specifications<br />
6ES7 671-<br />
0CC03-0YA0<br />
Memory/backup<br />
Memory<br />
Load memory<br />
- integral RAM, max. PC working<br />
memory<br />
usable<br />
CPU/blocks<br />
DB<br />
- Number, max. Limited only by<br />
the the amount<br />
of available<br />
PC working<br />
memory<br />
9/4<br />
Siemens ST 70 · 2005<br />
6ES7 671-<br />
0RC04-0YA0<br />
PC main memory<br />
can be<br />
used (non<br />
paged memory)<br />
Limited only by<br />
the the amount<br />
of available<br />
PC working<br />
memory<br />
- Size, max. 64 KByte 64 KByte<br />
FB<br />
- Number, max. Limited only by<br />
the the amount<br />
of available<br />
PC working<br />
memory<br />
Limited only by<br />
the the amount<br />
of available<br />
PC working<br />
memory<br />
- Size, max. 64 KByte 64 KByte<br />
FC<br />
- Number, max. Limited only by<br />
the the amount<br />
of available<br />
PC working<br />
memory<br />
Limited only by<br />
the the amount<br />
of available<br />
PC working<br />
memory<br />
- Size, max.<br />
OB<br />
64 KByte 64 KByte<br />
- Size, max. 64 KByte 64 KByte<br />
WinAC RTX:<br />
- The software solution for tasks which demand hard<br />
deterministics.<br />
- With real-time extension to provide deterministic behavior for<br />
the control unit.<br />
<strong>SIMATIC</strong> WinAC software PLCs each comprise the following<br />
components:<br />
Windows logic controller<br />
OPC server and ActiveX components<br />
Driver for PROFIBUS CPs<br />
VenturCom RTX real-time kernel (WinAC RTX only)<br />
Optional:<br />
CP for connecting to PROFIBUS DP:<br />
- CP 5611 or the integral PROFIBUS interface on the<br />
<strong>SIMATIC</strong> PC (WinAC Basis only)<br />
- CP 5613 A2.<br />
<strong>SIMATIC</strong> WinAC PN option<br />
- Permits communication between WinAC Basis and further<br />
automation systems based on PROFINET CBA via <strong>Industrial</strong><br />
Ethernet.<br />
WinAC Open Development Kit (ODK):<br />
- For using C/C++ code in WinAC Basis or WinAC RTX<br />
- For integrating external software (technology programs) or<br />
PC components (e.g. scanners, PC cards for measured data<br />
acquisition)<br />
6ES7 671-<br />
0CC03-0YA0<br />
6ES7 671-<br />
0RC04-0YA0<br />
CPU/blocks (continued)<br />
Nesting depth<br />
- per priority class 24 24<br />
- additional levels within an<br />
error OB<br />
CPU/processing times<br />
24 24<br />
for bit instruction, min. 0.013 µs; typ. 0.013 µs; typ.<br />
for integer math, min. 0.025 µs; typ. 0.025 µs; typ.<br />
for floating-point math, min. 0.025 µs; typ. 0.025 µs; typ.<br />
Reference platform Pentium IV, Pentium IV,<br />
Timers/counters and their<br />
retentive characteristics<br />
S7 counter<br />
2.4 GHz 2.4 GHz<br />
- Number<br />
Retentivity<br />
512 512<br />
- adjustable Yes Yes<br />
- lower limit 0 0<br />
- upper limit 511 511<br />
- preset<br />
Counting range<br />
8 8<br />
- adjustable Yes Yes<br />
- lower limit 0 0<br />
- upper limit 999 999