SIMATIC Industrial Software - Leocom
SIMATIC Industrial Software - Leocom
SIMATIC Industrial Software - Leocom
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
■ Technical specifications (continued)<br />
6ES7 673-<br />
2CC02-0YA0<br />
Timers/counters and their<br />
retentive characteristics<br />
(continued)<br />
IEC timer<br />
- available Yes Yes<br />
- Type SFB, unlimited<br />
quantity (only<br />
limited by working<br />
memory)<br />
S7 times<br />
-Number 256 512<br />
Retentivity<br />
- lower limit 0 0<br />
- upper limit 255 511<br />
- preset no timer is<br />
retentive<br />
6ES7 673-<br />
6CC22-0YA0<br />
SFB, unlimited<br />
quantity (only<br />
limited by working<br />
memory)<br />
no timer is<br />
retentive<br />
Timing range<br />
- lower limit 10 ms 10 ms<br />
- upper limit<br />
IEC timer<br />
9,990 s 9,990 s<br />
- available Yes Yes<br />
- Type SFB, unlimited SFB, unlimited<br />
quantity (only quantity (only<br />
limited by work- limited by work-<br />
Data areas and their<br />
retentive characteristics<br />
ing memory) ing memory)<br />
Retentivity without UPS and<br />
PS extension board<br />
No No<br />
Retentivity with UPS No No<br />
Retentivity with PS extension<br />
board and battery<br />
Flags<br />
all data all data<br />
-Number 4 KByte 16 KByte<br />
- of which retentive MB 0 to<br />
MB 4095<br />
MB 0 to<br />
MB 16383<br />
- preset retentivity MB 0 to MB 15 MB 0 to MB 15<br />
- Number of clock memories<br />
Address area<br />
I/O address area<br />
8 8<br />
- Inputs 4 KByte 16 KByte<br />
-Outputs<br />
of which distributed<br />
4 KByte 16 KByte<br />
- MPI/DP interface, inputs 2 KByte 2 KByte<br />
- MPI/DP interface, outputs 2 KByte 2 KByte<br />
- DP interface, inputs 4 KByte 8 KByte<br />
- DP interface, outputs<br />
Process image<br />
4 KByte 8 KByte<br />
- Inputs, adjustable 4 KByte 16 KByte<br />
- Outputs, adjustable 4 KByte 16 KByte<br />
- Inputs, preset 128 Byte 512 Byte<br />
- Outputs, preset 128 Byte 512 Byte<br />
- Number of component<br />
process images, max.<br />
Digital channels<br />
8 8<br />
- Inputs 32,768 81,920<br />
-Outputs<br />
Analog channels<br />
32,768 81,920<br />
- Inputs 2,048 5,120<br />
-Outputs 2,048 5,120<br />
PC-based Automation<br />
PC-based Control<br />
<strong>SIMATIC</strong> WinAC Slot PLC<br />
6ES7 673-<br />
2CC02-0YA0<br />
Configuration<br />
Number of DP masters<br />
- overall 2 2<br />
- integral 2 2<br />
Number of FMs and CPs that can<br />
be operated (recommendation)<br />
-FM FM distributed:<br />
FM 350-1,<br />
FM 350-2,<br />
FM 351,<br />
FM 352,<br />
FM 353,<br />
FM 354<br />
FM 355,<br />
FM 355-2<br />
Siemens ST 70 · 2005<br />
6ES7 673-<br />
6CC22-0YA0<br />
FM distributed:<br />
FM 350-1,<br />
FM 350-2,<br />
FM 351,<br />
FM 352,<br />
FM 353,<br />
FM 354,<br />
FM 355,<br />
FM 355-2<br />
- CP, LAN<br />
Time<br />
Clock<br />
via PC-CP via PC-CP<br />
- Hardware clock (realtime clock) Yes Yes<br />
- buffered<br />
Run-time meter<br />
Yes Yes<br />
- Quantity<br />
Time synchronization<br />
8 8<br />
- supported Yes Yes; (on PC-CP:<br />
Slave)<br />
- on PC-CP, slave Yes Yes<br />
- on MPI, master Yes Yes<br />
- on MPI, slave<br />
S7 message functions<br />
Yes Yes<br />
Number of stations that can log on<br />
for message functions, max.<br />
8 12<br />
SCAN method Yes Yes<br />
Process diagnostic messages Yes; (Alarm_S) Yes; (Alarm_S)<br />
Alarm 8 blocks Yes Yes<br />
Statuses<br />
Test and startup functions<br />
Yes Yes<br />
Status/modify<br />
- Variable<br />
Forcing<br />
Yes Yes<br />
- Forcing Yes Yes<br />
Status block Yes Yes<br />
Single step<br />
Diagnostic buffer<br />
Yes Yes<br />
- available Yes Yes<br />
- Number of inputs, max. 400 3,200<br />
- preset<br />
Communication functions<br />
120 120<br />
PG/OP communication<br />
Global data communication<br />
Yes Yes<br />
- supported<br />
S7 basic communication<br />
Yes Yes<br />
- supported<br />
S7 communication<br />
Yes Yes<br />
- as server Yes Yes<br />
- as client<br />
Number of connections<br />
Yes Yes<br />
- overall 16 64<br />
- reserved for PG communication 1 1<br />
- reserved for OP communication 1 1<br />
9/9<br />
9