■ Technical specifications (continued)<br />

2nd interface<br />

6ES7 636-2EC00-0AE3<br />

Type of interface integrated RS 485 interface<br />

Physical RS 485<br />

Isolated Yes<br />

Power supply to interface<br />

(15 to 30 V DC), max.<br />

200 mA<br />

Number of connection resources<br />

Functionality<br />

16<br />

-MPI No<br />

-DP master Yes<br />

- DP slave<br />

DP master<br />

Yes<br />

- Number of connections, max. 16; for PG/OP communication<br />

- Number of connections<br />

(of which reserved), max.<br />

Services<br />

1 for PG, 1 for OP<br />

- PG/OP communication Yes<br />

- Routing Yes<br />

- Global data communication No<br />

- S7 basic communication No<br />

- S7 communication No<br />

- S7 communication, as client No<br />

- S7 communication, as server No<br />

- Equidistance support Yes<br />

- SYNC/FREEZE Yes<br />

- Activate/deactivate DP slaves Yes<br />

- Direct data exchange (lateral<br />

communication)<br />

Yes<br />

- Transmission rates, max. 12 Mbit/s<br />

- Number of DP slaves, max.<br />

Address area<br />

125<br />

- Inputs, max. 244 Byte<br />

-Outputs, max.<br />

DP slave<br />

244 Byte<br />

- Number of connections<br />

Services<br />

16<br />

- PG/OP communication Yes<br />

- Routing Yes<br />

- Global data communication No<br />

- S7 basic communication No<br />

- S7 communication No<br />

- Direct data exchange<br />

(lateral communication)<br />

Yes<br />

- Transmission rates, max.<br />

Intermediate memory<br />

12 Mbit/s<br />

- Inputs 244 Byte<br />

-Outputs 244 Byte<br />

- Address areas, max. 32<br />

- User data per address area,<br />

max.<br />

32 Byte<br />

CPU/ programming<br />

Configuration software<br />

<strong>SIMATIC</strong> C7<br />

Control systems<br />

6ES7 636-2EC00-0AE3<br />

Siemens ST 70 · 2005<br />

C7-636<br />

- STEP 7 Yes; as of V5.2 SP1 and HSP<br />

- ProTool Yes; as of Version 6.0 SP2 and<br />

Setup C7-636<br />

- ProTool/Lite Yes; as of Version 6.0 SP2 and<br />

Setup C7-636<br />

- ProTool/Pro<br />

Programming language<br />

Yes; as of Version 6.0 SP2 and<br />

Setup C7-636<br />

-LAD Yes<br />

-FBD Yes<br />

-STL Yes<br />

-SCL Yes<br />

-CFC Yes<br />

- GRAPH Yes<br />

- HiGraph ® <strong>Software</strong> library<br />

Yes<br />

Instruction set see instruction list<br />

Bracket levels 8<br />

User program protection/<br />

password protection<br />

Yes<br />

System functions (SFC) see instruction list<br />

System function blocks (SFB)<br />

Integrated inputs/outputs<br />

see instruction list<br />

Default addresses of the integral<br />

- Digital input 124.0 to 126.7<br />

- Digital outputs 124.0 to 125.7<br />

- Analog inputs 752<br />

- Analog outputs 761<br />

Digital inputs<br />

Number of digital inputs 24<br />

- which can be used as inputs 16<br />

for technological functions<br />

Number of inputs that can be driven<br />

in parallel<br />

vertical mounting positions<br />

- up to 40°C 18<br />

horizontal mounting positions<br />

- up to 40°C 12<br />

Length of cable<br />

- Length of cable shielded, max. 1,000 m; 100 m for<br />

technological functions<br />

- Length of cable unshielded, 600 m<br />

max.<br />

Technological function<br />

- shielded, max. 50 m; at maximum<br />

count frequency<br />

- unshielded, max. not allowed<br />

Standard DI<br />

- shielded, max. 1,000 m<br />

- unshielded, max. 600 m<br />

Input characteristic to comply with Yes<br />

IEC 1131, Type 1<br />

6/25<br />

6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!